HPR 400 Transceiver Unit
12
130314 / F
- This connector is not used with the HPR 400 P.
10
25-pin D-connector for Parallel input.
- This connector is not used with the HPR 400 P.
11
25-pin D-connector for Analogue input/output.
- This connector is used to connect an analogue Vertical
Reference Unit. Any of the following types of VRU
may be used:
- Piro 40
±
15
°
- Piro 40
±
90
°
- PMT Accustar
±
60
°
- Shaevitz
±
4.5
°
- MRU
±
20
°
12
15-pin D-connector for Gyro input (syncro)
- This connector is used to connect a syncro gyro. The
following input types are supported:
* 26 V / 400 Hz
* 115 V / 400 Hz (Option)
13
3-pin Amphenol connector for Responder 1. (Optional)
14
3-pin Amphenol connector for Responder 2.
15
3-pin Amphenol connector for Responder 3.
16
3-pin Amphenol connector for Responder 4.
17
3-pin Amphenol connector for Transducer 3.
- This transducer connector is used with dunking
transducers.
18
3-pin Amphenol connector for Transducer 4.
- This transducer connector is used with dunking
transducers.
19
35-pin Amphenol connector for Transducer 1.
- This transducer connector is used with PMT 301, SSBL
MF medium, SSBL MF narrow and SSBL LF medium
transducers.
20
35-pin Amphenol connector for Transducer 2.
- This transducer connector is used with PMT 301, SSBL
MF medium, SSBL MF narrow and SSBL LF medium
transducers.
All connectors are marked with labels as indicated on the