HPR 400 Transceiver Unit
2
130314 / F
TECHNICAL SPECIFICATIONS
Transceiver Unit
Height
135 mm
Width
483 mm
Depth
310 mm
Weight
Approximately 20 kg
6U cabinet
Height
371 mm
Width
600 mm
Depth
480 mm
Weight
Approximately 43 kg
Refer to drawing no. 830-102971 in the drawing file for further
details of the 6U cabinet dimensions.
Power supply
Voltage
196 to 253 Vac, 1 phase or
39 to 64 Vdc
Frequency
50 - 60 (47-63) Hz
Power consumption
55 W
Maximum current
10 A
The power supply must be kept within
±
10% of the unit’s
nominal voltage. The maximum transient voltage variations on
the main switchboard’s bus-bars which could occur (except
under fault conditions), are not to exceed -15% to +20% of the
nominal voltage.
Environmental
Temper ature:
Storage
-20 to +65
°
C
Operational
0 to +55
°
C