64
472405/A
Installation of dual RX system
Adding a second receive transducer increases the angular coverage.
In a dual RX system, the transmit transducer must be connected to both receive
transducers. This connection is for synchronization and power.
In a dual RX installation the two RX transducer arrays may be positioned on each side
of the keel with a roll angle of 35 to 40 degrees. To be able to cover ± 100 degrees the
roll installation angle should not be less than 35 degrees. To obtain overlap between the
two RX arrays at shallow depths, the roll installation angle should not be more than
40 degrees, and the across distance between the two RX arrays should be as small as
possible.
For specialist applications such as pipeline inspection, other configurations can be
recommended depending on the application in question. Contact Kongsberg Maritime to
get advice about your installation.
KONGSBERG EM 2040 MKII Installation Manual
Summary of Contents for EM 2040 MKII
Page 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Page 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Page 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Page 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Page 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Page 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Page 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Page 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Page 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Page 247: ......
Page 248: ...2021 Kongsberg Maritime...