Cable glands and termination procedures
Cable glands are used to attach and secure the end of a cable to the equipment. Cable
glands may also be used for sealing cables passing through bulkheads or gland plates.
About cable glands
Cable glands are used whenever a cable passes through a watertight bulkhead or into
a cabinet, to seal the opening through which the cable passes and to protect the cable
from abrasion on the edges of the hole.
There are many different types of cable gland on the market. The cable glands are not
supplied with the system.
Note
Even though the cabinets from Kongsberg Maritime may be prepared for specific types
of cable glands, the installation shipyard will be responsible for selecting cable gland
types and installing them.
A cable gland (in the U.S. more often known as a cable connector or fitting) is
a device designed to attach and secure the end of a cable to the equipment. A
cable gland provides strain-relief and connects by a means suitable for the type
and description of cable for which it is designed—including provision for making
electrical connection to the armour or braid and lead or aluminium sheath of the
cable, if any. Cable glands may also be used for sealing cables passing through
bulkheads or gland plates.
Cable glands are mechanical cable entry devices and can be constructed from
metallic or non-metallic materials. They are used throughout a number of industries
in conjunction with cable and wiring used in electrical instrumentation and
automation systems.
Cable glands may be used on all types of electrical power, control, instrumentation,
data and telecommunications cables. They are used as a sealing and termination
device to ensure that the characteristics of the enclosure which the cable enters
can be maintained adequately.
http://en.wikipedia.org/wiki/Cable_gland (February 2014)
Preparing cables for termination
Whenever a cable shall penetrate a cabinet or a bulkhead using a cable gland, the
termination of the cable must be prepared.
Prerequisites
Electrical installations can only be done by certified electricians. All necessary tools and
instruments required must be available. The installation shipyard must prepare detailed
drawings of the electrical system, and identify each cable.
Summary of Contents for EM 2040 MKII
Page 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Page 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Page 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Page 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Page 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Page 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Page 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Page 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Page 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Page 247: ......
Page 248: ...2021 Kongsberg Maritime...