background image

 

37

8.3 Instruction of Menu Bar Window of PC Terminal Software of OTDR 

Menu  bar  window  of  PC  terminal  software  of  OTDR  Traces  Manager  includes  5  menu 

options: file, editing, view, help, and language. 

 

Fig.8-2. Interface Diagram of Menu Bar Window of PC Terminal Software of OTDR 

8.3.1 Instruction of Menu“File” 

The menu“File”is shown as Fig.8-3. Functions can be realized in the menu“file”include: 

open/close trace file, save/save as the current curve, save all curves, print the option, print, print 
preview, batch modifying, batch print/ multi traces print on single page/ display and print multi 
traces, escape the application software. 

 

Fig.8-3 Interface Diagram of Menu“File” 

1)  “Open/close/close all files” 

“Open dialog box”will eject after selecting the function“Open”, as shown in Fig.8-4. 

Users can choose at most 8 trace files in a same folder through“Ctrl + mouse”; the selected file 
will be in the“list of multi-waveform displayed file”. The opened trace file can be closed by 
selecting“close file”or“close all files”in the menu“file”. 

 
 
 
 
 
 
 
 
 

Summary of Contents for OTDR QX50

Page 1: ...Optical Time Domain Reflectometer KomShine QX50 OTDR User Manual...

Page 2: ...the current operation effect Up down buttons Select the desired menu icon On the keyboard or drop down list select the corresponding characters or data In the folder tree structure window realize the...

Page 3: ...with buttons can realize combination functions of transversal amplifying and reducing of trace On the home page of OTDR function module the button used together with button can realize the fast switc...

Page 4: ...Main Interface of OTDR 18 7 1 3 Instruction of Info Window Area of the Main Interface of OTDR 19 7 1 4 Instruction of Status Bar Area on the Main Interface of OTDR 21 7 2 Instruction of Menu Button Se...

Page 5: ...t of Multi traces Displaying File 48 8 5 3 Displaying Area of Measurement Parameter 48 8 5 4 Displaying Area of Measurement Result 48 8 6 Instruction of Event List Window of PC Terminal Software of OT...

Page 6: ...e Any change of the information in the manual won t be notified We won t guarantee anything about the material including but not limited to hint guarantee for marketability and adaptability of dedicat...

Page 7: ...he Manual Warning symbol indicates danger existed It informs users pay attention to a certain process a certain operation method or similar conditions If operate wrongly or violate rules bodily injury...

Page 8: ...injured and corroded Outside power supply All OTDR series can use outside power supply Requirements of power supply DC12V 3A polarity Avoid laser radiation during measuring processing of optical fibe...

Page 9: ...8 3 Appearance Diagram of OTDR Product Fig 3 1 Appearance Diagram of OTDR...

Page 10: ...charging the battery the indicator is turned on to be green when charging finished the indicator will turn off automatically LAN Ethernet Interface Several models have such interface Audio Interface S...

Page 11: ...y the current operation effect Up down buttons Select the desired menu icon On the keyboard or drop down list select the corresponding characters or data In the folder tree structure window realize th...

Page 12: ...with buttons can realize combination functions of transversal amplifying and reducing of trace On the home page of OTDR function module the button used together with button can realize the fast switc...

Page 13: ...TDR optical time domain reflectometer and VFL visual fault location Directly clicking OTDR or VFL can enter into the operation page of their functional modules As shown in the following figure 4 1 Ope...

Page 14: ...x of auto turn off setting is ejected Operator can conduct corresponding setting on the dialog box Auto turn off function provides options of OFF after 5 min after 10 min after 30 min after 1 hour aft...

Page 15: ...truction and monitoring of cable line It can measure the optical fiber length transmission attenuation of optical fiber attenuation of splice and failure location etc When the pulse being transmitted...

Page 16: ...screen is the abnormal points in the optical fiber that led to deviation of trace which are classified with special symbols on the trace Events include reflection event and non reflection event 6 3 1...

Page 17: ...OTDR sends optical pulse into the optical fiber that waited for inspection then begins to accept the returned optical signal immediately and calculate the distance of event in the optical fiber The fu...

Page 18: ...roduction to Operation of OTDR 7 1 Instruction of Home Page Screen of OTDR The trace displayed on the screen that measured by OTDR is shown in Fig 7 1 Fig 7 1 Interface Diagram Displayed on the Screen...

Page 19: ...lifying indicates longitudinally amplifying the measured trace with the intersection of the chosen sign post and the trace as center Longitudinal reducing indicates longitudinally reducing the measure...

Page 20: ...e link length link loss link attenuation coefficient and quantity of event Definition and setting of file name duration of measurement and measurement date are shown in set menu When looking over info...

Page 21: ...the last event point to the current event point Echo loss reflect the reflection value of the event point Accumulate loss indicates the loss value of optical fiber from the initial point to the curre...

Page 22: ...of measurement starting and stopping and will prompt measurement status in the status bar of the measurement model Display of measuring progress status bar when clicking the icon button measurement OT...

Page 23: ...10 Interface Diagram of Menu Set 7 2 1 Parameter Setting Fig 7 11 Interface Diagram of Menu Parameter Setting laser wavelength Distance scope pulse width duration of measurement measurement model ref...

Page 24: ...role in the measurement Length unit meter No option or user setting is provided in OTDR instrument Refractivity set by user input scope 1 0000 1 9999 default value is set to be 1 4685 Back scattering...

Page 25: ...le will be automatically named and set to ON status The auto naming category is optional Automatic storage file is the presence of SD card under the root directory when the OTDR is not inserted the SD...

Page 26: ...Bundling threshold line selected by user options include ON and OFF the default value is OFF Bundling threshold line is marked with red dotted line Screen brightness adjustment selected by user option...

Page 27: ...nated and warning prompt should be given Prompt mode warning dialog box ejects The accuracy of the data measured by OTDR instrument is closely related to the connection status of the connector of the...

Page 28: ...imultaneously If the file setting is saving after finishing multi wavelength measurement click the menu icon saving to save the trace files When saving it will circularly prompt whether save the corre...

Page 29: ...28 unfolded subfolders function through the enter button on the folder options and confirming function Fig 7 15 Interface Diagram of Menu Saving...

Page 30: ...en will eject In the key mode of operation through the SHIFT button to achieve circular switching function for each window through the button to achieve the path choice of the folded or unfolded subfo...

Page 31: ...er renaming file folder copying and file folder deletion can be fulfilled In the key mode of operation through the SHIFT button to achieve circular switching function for each window through the butto...

Page 32: ...es Analysis 7 7 1 Instruction of Button Multi traces Setting Click the button icon multi traces setting in the multi waveform analysis dialog box multi traces setting will eject By clicking the icon b...

Page 33: ...e displayed window through trace remove operation The remove operation is only valid for the current trace After remove the current trace the next smallest SN trace will be adjusted to be the current...

Page 34: ...i e lock the current displayed trace in the trace graph area when clicking the button trace unlock the locking function is relieved Trace locking function can lock one trace each time The locked trac...

Page 35: ...ton Help of OTDR After clicking the button help the table of contents will eject Contents looked over can be selected according the table of contents 7 10 Instruction of Menu Button Home Page of OTDR...

Page 36: ...OTDR Traces Manager is as follows z Pentium 3 or Pentium 4 or private computer with similar configuration z Microsoft Windows98 2000 XP 7 operation system z Available space of hardware is larger than...

Page 37: ...following several parts menu bar window toolbar window waveform window including trace graph multi waveform displaying file list measurement parameter measurement result event list window the whole wa...

Page 38: ...ile save save as the current curve save all curves print the option print print preview batch modifying batch print multi traces print on single page display and print multi traces escape the applicat...

Page 39: ...current curve save all curves save the current curve as When selecting save the current modified curve save all modified curve and save the current curve as another file the dialog box shown in Fig 8...

Page 40: ...trace information trace graph including mesh sign post bundling threshold line event point marks thumbnail parameter information optical fiber link and event list Its default value option is trace in...

Page 41: ...40 4 Batch Modifying Batch modifying only allows batch modifying of information in trace file under the same file folder as shown in Fig 8 7 Fig 8 7 Interface Diagram of Dialog Box Batch Modifying...

Page 42: ...e display and print multi traces only allows print mode of trace file under the same folder a Batch print The print mode only allows print format of single trace in single page of trace file under the...

Page 43: ...e 4 waveform page 6 waveform page or 8 waveform page needs to be selected firstly Each page setting corresponds to different formats In addition under the print mode the first selected trace file i e...

Page 44: ...rinting trace files will display the corresponding figure and wave length information In addition under the print mode the first selected trace file i e the uppermost one is defined as the master file...

Page 45: ...e trace information editing event increasing event modifying and event deleting Through trace information editing one can realize trace information modifying of the trace file through event increasing...

Page 46: ...nsversal longitudinal amplifying reducing whole trace displaying displaying concealing of relevant tool buttons for AB scale plate AB line locking switching displaying concealing of relevant tool butt...

Page 47: ...l Software Toolbar Window of OTDR Fig 8 14 Interface Diagram of Toolbar Window The toolbar window is under the menu bar window The purpose of toolbar window is to make the main functions under the men...

Page 48: ...aph area as shown in Fig 8 16 The lateral axis represents the distance unit m while the vertical axis represents the back scattering power Unit dB The 11 icon buttons in the right of trace graph area...

Page 49: ...hrough the right key of mouse functions of trace information opening closing and editing of a single file can be realized List of multi traces displaying file is as shown in Fig 8 17 Fig 8 17 Schemati...

Page 50: ...ion quantity of the reflection event Accumulate loss indicating the attenuation dB value of the optical fiber from the connector of OTDR instrument and the optical fiber tested to the event Note note...

Page 51: ...e needs to be wiped periodically with dedicated alcohol After using cover the dust cap meanwhile keep the cleanness of the dust cap In addition clean the connector of flange periodically There is no n...

Page 52: ...ay attention to the follows You d better store the instrument including battery under room temperature 15 to 30 and place it at dry place to keep its best performance If the instrument is left unused...

Page 53: ...ge caused from maintenance or treatment by unauthorized personnel or non our technicians z Anti dismounting labels are torn up z Serial number of the equipment is modified erased or worn z Equipment d...

Page 54: ...guarantee scope user should pay the expense stated on the maintenance report If the equipment is within the guarantee scope we will pay the back freight To accelerate problem treatment process please...

Page 55: ...ange the button board Problem 3 data saving aren t allowed Possible reason SD card is used up Solving method Export the curve to empty the memory z Optical fiber connection problem Improper optical fi...

Page 56: ...fiber or the length that found by the automatic measurement model Problem 7 Only partial trace is displayed which causes test failed Possible reason The set testing distance is too short Solving metho...

Page 57: ...66 Optical interface FC UPC PC and APC are selectable Weight 1 5kg Data interface USB interface SD card interface Running temperature 10 to 50 Temperature Memory temperature 40 to 70 Visible failure...

Page 58: ...tion KomShine Technologies Limited Add 1F Building 2 Huashen Technology Park Yuhua district Nanjing JS 210012 P R China Call us 86 25 8687 1288 Fax us 86 25 8687 1388 e mail sales komshine com Website...