31
KOMPATTO
installation, use and maintenance manual
Service function
Cleaning
Descaling
Date and time
Parameters
Backlight
fig. 52
fig. 51
6. Service Menu
6.1. Self-cleaning (cleaning the washing nozzle)
Ovens equipped with high performance boil-
ers (model
KH...
) should be descaled peri
-
odically to keep the latter efficient and re
-
duce the risk of damage.
Ask your installer for advice on intervention
frequency. Make sure that the conditions
of water hardness comply with the recom-
mended parameters (60-120 ppm).
In case
of water hardness greater than 120
ppm, it is recommended to install a wa-
ter softener upstream of the oven
.
Perform descaling by accessing the
Service
menu. Use the dial
M
to select the option
Descaling
and press
Start.
The oven will start to empty the boiler and
then the operator will be asked to introduce
0.4 L of vinegar through the steam inlet
of the cooking chamber (left innner side).
Descaling will start automatically. The oven
shuts down upon completion.
6.2. Boiler descaling (for models KH..only)
The cleaning nozzle should be cleaned peri-
odically in a dishwasher.
Loosen the screws
A
and remove the nozzle,
pulling it downwards.
After cleaning, re-insert the nozzle into its
slot by pushing it upwards and tighten the
screw
A
.
A
Summary of Contents for KH061
Page 8: ...8 tab 1...
Page 45: ...45 KOMPATTO installation use and maintenance manual 12 Wiring diagrams 12 1 KH0623 W...
Page 46: ...46 12 Wiring diagrams 12 2 KH061 W...
Page 47: ...47 KOMPATTO installation use and maintenance manual 12 Wiring diagrams 12 3 KH0101 W...
Page 48: ...48 12 Wiring diagrams 12 4 KT0623 W...
Page 49: ...49 KOMPATTO installation use and maintenance manual 12 Wiring diagrams 12 5 KT061 W...
Page 50: ...50 12 Wiring diagrams 12 6 KT101 W...
Page 52: ...0051...