FOREWORD
PUSH-PULL COUPLER
00-28
WA500-6
PUSH-PULL COUPLER
00
Type 1
00
Disconnection
00
1.
Release the residual pressure from the hydraulic tank.
★
For details, see
WORK EQUIPMENT: Releasing Residual
Pressure in Hydraulic Circuit
in the
Testing and Adjusting
section.
2.
Hold the adapter (1) and push the hose joint (2) into the mating
adapter (3). The adapter can be pushed in about 3.5 mm (0.14 in).
Do not hold the rubber cap portion (4).
3.
After the hose joint (2) is pushed into the adapter (3), press the
rubber cap portion (4) against the adapter until it clicks.
4.
Hold the hose adapter (1) or hose (5) and pull it out. Since some
hydraulic oil flows out, prepare a container to receive the oil.
Connection
00
1.
Hold the hose adapter (1) or hose (5) and insert it in the mating
adapter (3), aligning them with each other. Do not hold the rubber
cap portion (4).
2.
After inserting the hose in the mating adapter, pull it back to check
its connecting condition. When the hose is pulled back, the rubber
cap portion moves toward the hose about 3.5 mm (0.14 in). This
does not indicate an abnormality.
WARNING!
Before carrying out the following work, release the
residual pressure from the hydraulic tank. For
details, see
WORK EQUIPMENT: Releasing
Residual Pressure in Hydraulic Circuit i
n the
Testing and Adjusting section.
WARNING!
Even if the residual pressure is released from the
hydraulic tank, some hydraulic oil flows out when
the hose is disconnected. Prepare a container to
receive the oil.