159
3.15.4 OTHER TROUBLES
(•) Always contact your Komatsu Dealer when you have to carry out this operation.
•
If the anomaly or its cause is not included in the table below, contact your Komatsu Dealer for the necessary
repair.
3.15.4.1 ELECTRICAL CIRCUIT
3.15.4.2 HYDRAULIC SYSTEM
TROUBLE
CAUSE
REMEDY
Lights do not work satisfactorily even
with engine running at high speed:
• Faulty cables.
• Faulty fan belt tension.
(•) Check and repair any loose terminal
and connection.
• Adjust fan tension
(see “EVERY 250 HOURS).
Lights come on intermittently with
engine running:
Alternator charge warning light does not
go out with engine running and
increasing speed:
• Faulty alternator.
• Faulty cables.
(•) Change.
(•) Check and repair.
Alternator emits an abnormal noise:
• Faulty alternator.
(•) Change.
Starter does not turn with key in START
position:
• Faulty cables.
• Battery charge insufficient.
• Faulty engine start fuse.
(•) Check and repair.
• Charge the battery.
• Change.
Starter pinion engages and then
disengages:
• Battery charge insufficient.
• Charge the battery.
Starter makes engine run slowly:
• Battery charge insufficient.
• Faulty starter.
• Charge the battery.
(•) Change.
Starter disengages before engine has
started:
• Faulty cables.
• Battery charge insufficient.
(•) Check and repair.
• Charge the battery.
Engine oil pressure warning light does
not come on when engine is stopped
(ignition key in position
« »):
• Faulty bulb.
• Faulty pressure sensor.
(•) Change.
(•) Change.
Alternator charge warning light does not
come on when engine is stopped
(ignition key in position « »):
• Faulty bulb.
• Faulty cables.
(•) Change.
(•) Check and repair.
TROUBLE
CAUSE
REMEDY
Pump emits an abnormal noise:
• No oil in the tank.
• Faulty pump.
• Hydraulic oil unsuitable for the
temperature.
• Top up.
(•) Repair or change.
• Change.
Equipment control levers do not return
automatically to neutral position:
• Broken return spring or seized
element.
(•) Change spring or distributor
element.
Equipment moves only at low speed:
• Faulty pump.
• Max. pressure valves out of rating,
or not closed due to impurities.
• Dirty drain filter.
(•) Repair or change.
(•) Calibrate or change.
• Change.
https://tractormanualz.com
Summary of Contents for Utility WB97S-5
Page 2: ...https tractormanualz com ...
Page 21: ...SAFETY AND ACCIDENT PREVENTION 19 https tractormanualz com ...
Page 64: ...62 THIS PAGE WAS INTENTIONALLY LEFT EMPTY https tractormanualz com ...
Page 65: ...THE MACHINE AND ITS OPERATIONS 63 https tractormanualz com ...
Page 164: ...162 THIS PAGE WAS INTENTIONALLY LEFT EMPTY https tractormanualz com ...
Page 165: ...MAINTENANCE 163 https tractormanualz com ...
Page 233: ...TECHNICAL SPECIFICATIONS 231 https tractormanualz com ...
Page 240: ...238 THIS PAGE WAS INTENTIONALLY LEFT EMPTY https tractormanualz com ...
Page 241: ...AUTHORISED OPTIONAL EQUIPMENT 239 https tractormanualz com ...
Page 279: ...https tractormanualz com ...