OPERATION
TROUBLES AND ACTIONS
Starting the Engine
CAUTION
Always check that the lock lever is set to the LOCK position, regardless of whether the machine is working normally or has failed.
Check also that all the control levers are at the HOLD or neutral position.
1. Make sure the clips are firmly connected to the battery terminals.
2. Start engine of the normal machine and run it at high idle speed.
3. Turn the starting switch of the problem machine to the START position and start the engine.
If the engine doesn't start at first, try again after 2 minutes or so.
Booster Cable Disconnection
After the engine has started, disconnect booster cables in the
reverse order in which they were connected.
1. Remove one clip of booster cable (B) from the engine block of
the problem machine.
2. Remove the other clip of booster cable (B) from the negative (-)
terminal of the normal machine.
3. Remove one clip of booster cable (A) from the positive (+)
terminal of the normal machine.
4. Remove the other clip of booster cable (A) from the positive (+)
terminal of the problem machine.