METHOD FOR REPLACING AIR CONDITIONER FRESH/RECIRC FILTERS
Since the filtering ability of the filters decreases as they are aged, replace them every 500 operating hours or
every year.
METHOD FOR REPLACING RECIRCULATION AIR FILTER
1.
Turn knob (1) at the back of the operator's seat, and re-
move recirculation air filter (2).
2.
Install the new recirculation air filter (2), and tighten knob
(1).
When fixing it with knob, check the filter position by touch-
ing it with hands or looking at it, and then tighten it.
METHOD FOR REPLACING FRESH AIR FILTER
1.
Open the hydraulic tank inspection cover on the left side of
the machine, and check the position of step (1).
Use step (1) to remove or install the fresh air filter.
MAINTENANCE
MAINTENANCE PROCEDURE
4-55