PROCEDURE FOR AFTERTREATMENT DEVICES REGENERATION DISABLE
SETTING
If there is combustible material around the machine and the active regeneration that increases the exhaust tem-
perature must not be performed, the automatic active aftertreatment devices regeneration can be disabled. Al-
so, the regeneration in progress can be stopped.
NOTICE
Even if the regeneration is disabled, KDPF soot accumula-
tion caution lamp (1) lights up if soot is accumulated and
the manual stationary regeneration is required. If KDPF
soot accumulation caution lamp lights up, move the ma-
chine to a safe place and perform manual stationary regen-
eration.
If the operation is continued without performing the man-
ual stationary regeneration, it may cause the failure of
KDPF or the engine.
While regeneration is not being performed: Setting for regeneration disable
(When aftertreatment devices regeneration pilot lamp is lit on the standard screen)
1.
On the standard screen, press switch F6.
2.
Operate switches F1 and F2 to select “Aftertreatment De-
vices Regeneration” menu (C) and display the “Aftertreat-
ment Devices Regeneration” screen.
3.
Select “Regeneration Disable” and press switch F6, then
the regeneration function is disabled and the regeneration
cannot be performed.