(1) Angle cylinder head pin (1 place each of right and left)
(2) Tilt cylinder bottom pin (1 place)
(3) Tilt cylinder head pin (1 place)
METHOD FOR LUBRICATING EQUALIZER BAR SIDE PIN
(1 place each on right and left sides)
1.
Remove all soil and sand from the top of the track frame
and top of the cover.
2.
Clean the grease fitting shown by arrow.
3.
Supply grease by using a grease pump.
REMARK
• Supply 3 shots of grease (Operate the grease pump
lever 3 times) to each grease fitting, and check that
grease is newly discharged through the seal lip.
• If grease is not newly discharged through the lip por-
tion, continue supplying grease until it is discharged.
• If the blade is lowered to raise the idler 1 to 2 cm from
the ground in order when performing lubrication, the
grease will fill the whole circumference of the pin.
METHOD FOR CHECKING OIL LEVEL IN FINAL DRIVE CASE, ADDING OIL
k
k
WARNING
• Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
• If there is remaining pressure inside the case, the oil or plug may jump out. Loosen the plug slowly
to release the pressure.
Prepare a handle for the work.
MAINTENANCE PROCEDURE
MAINTENANCE
4-44
Summary of Contents for D51EX-24