![Komatsu D51EX-24 Operation & Maintenance Manual Download Page 223](http://html1.mh-extra.com/html/komatsu/d51ex-24/d51ex-24_operation-and-maintenance-manual_1991127223.webp)
• Reverse travel speed can be set with reverse travel speed
setting switch (A) and (B).
• Each time switch (A) is pressed, the set travel speed in-
creases.
• Each time switch (B) is pressed, the set travel speed de-
creases.
• Lower bar graph (H) indicates the reverse travel speed.
• Turn the starting switch in ON position and start the en-
gine, reverse travel speed is set approximately 20 % faster
than the forward travel speed.
• Depress switch (A) once, and the reverse travel speed be-
comes the same as the forward travel speed.
• 3rd speed is the maximum, so reverse travel speed cannot
be set faster than that.
METHOD FOR SWITCHING BETWEEN FORWARD AND REVERSE
k
k
WARNING
When switching the travel direction between FORWARD
and REVERSE, check the safety in new direction in which
the machine moves.
k
k
CAUTION
There is no need to stop the machine even when switching
between FORWARD and REVERSE. To increase safety, op-
erator comfort, and the life of the power train system, do
not leave the engine running at full speed while switching
the direction, and always depress the decelerator/brake
pedal to lower the engine speed.
1.
Depress decelerator/brake pedal (1) to reduce the engine
speed.
OPERATION
MACHINE OPERATIONS AND CONTROLS
3-167