Through UP/DOWN keys, select “YES” t
o set the sequence
or “NO”
to remain in single
program
-
Push OK to confirm.
Once you set the sequence, you can modify only the number of the screws, the min and the max
time but not the number of program you are in.
8) Sequence: you can set a sequence up to 4 programs. Each program can be repeated:
-
Push OK to enter
-
Set the number of cycle per program (2, 3, 4) through UP/DOWN and push O
-
Set each single program through UP/DOWN and push OK
Once set the last program, the unit will save automatically the data. The sequence will be
shown on the display.
9) Statistic:
-
Screws OK
-
Screw NOT-OK
-
Cycles done
-
Sequences done correctly
Functioning:
-
Push OK to enter
-
All the data are visualized, then push OK to go on
-
RESET ALL?: select YES through UP/DOWN to reset all the data or NO
-
PRINT ALL: select YES through UP/DOWN to print all the data or NO
5.Connectors
Warning: a wrong connection may cause irreversible damage to this device, ensure that tensions
and connections are made by skilled technicians. Read the operating instructions before connecting
external systems and ensure that tensions and external signals are within the limits of the device.
Any tampering or damage caused by improper use of the device are not covered by warranty.
On the back panel, there are 2 connectors:
A) In/Out screwdriver
B) Output signals
C) Connection to external keyboard for a remote control
D) Remote suspension of cycle.
A) To be connected to the control unit:
1) Stop motor
2) Lever: start signal (lever pressed)
3) Torque: torque signal
4) 0 GND: common signal