DISPLAY BRIGHTNESS: increase or decrease the brightness of the touch screen display
(10)
PASSCODE
Enables or disables the passcode lock for the configuration menu.
Tap the input field to enter a passcode, and enable the on/off toggle to activate it.
When the passcode is enabled, the lock icon on the main screen will have a red
background, and the passcode will be required to access the configuration menu.
Should you forget the passcode, contact Kolver to obtain a master passcode.
(11)
DATE & TIME
Tap to change the date and time of the unit. This changes the date and time associated
with each (new) result reported in the serial print, usb, and modbus fields.
(12)
TOUCH SCREEN CALIBRATION
Tap to enter the touch screen calibration function. Use this to correct problems with the
alignment of the touch response of the display.
Touch the four blue dots with one finger where they appear on the screen. Contact
Kolver if the problem persists.
(13)
INFO
Tap to show the firmware versions loaded onto the unit and onto the connected KDS
screwdriver.
(14)
COMMUNICATION PROTOCOL
PROTOCOL: select the communication protocol to use between the following options:
K-EXPAND: to interface with the free K-EXPAND PC software via the MiniUSB port.
MODBUS TCP: to interface with any device supporting the MODBUS TCP protocol
via the ethernet port.
IP ADDRESS: the ethernet IP address of the K-DUCER unit. Must be assigned manually
and be available/reserved in the local network, if applicable. The unit does not support
DHCP assignment.
GATEWAY: the ethernet IP address of the local network gateway, if applicable. You can
leave this as 0.0.0.0 in most cases.
DNS: the ethernet IP address of the local DNS server. You can leave this as 0.0.0.0 in
most cases.
SUBNET MASK: the subnet mask of the local network. The value must match the
subnet mask of the other devices in the LAN. Usually this value is 255.255.255.0. Note
that 0.0.0.0 will not work in most cases. Contact your IT support if unsure.
MAC ADDRESS: shows the MAC address of the K-DUCER (v35 and later).
Note: to find the MAC address of the K-DUCER unit with firmware versions v34 and
earlier: set COMMUNICATION PROTOCOL to OP or MODBUS TCP, then connect to a
PC connected to the same LAN network. If connecting CN1 directly to an ethernet port
on your PC, make sure to set your PC’s IP address to static with the same subnet mask
of the K-DUCER.
For example:
Summary of Contents for 033001
Page 1: ...KDU NT and KDS NT Torque range 5 70 cNm 7 100 ozfin OPERATOR MANUAL Patent pending...
Page 13: ...Vers 111422 13 Threaded M3 fixturing holes side holes on CA models only...
Page 44: ...Vers 111422 44 PROGRAMS menu tree...
Page 45: ...Vers 111422 45...
Page 46: ...Vers 111422 46...
Page 47: ...Vers 111422 47...
Page 58: ...Vers 111422 58 SEQUENCE SETTINGS menu tree...
Page 68: ...Vers 111422 68 USB menu tree...
Page 72: ...Vers 111422 72 Pinout CN5...
Page 83: ...Vers 111422 83 EXPLODED VIEW KDS NT70 KDS NT70 HM...
Page 84: ...Vers 111422 84...
Page 85: ...Vers 111422 85...
Page 86: ...Vers 111422 86 SPARE PARTS KDS NT70 KDS NT70 HM Lever Kit HM Half Moon model...
Page 87: ...Vers 111422 87 EXPLODED VIEW KDS NT70CA KDS NT70CA HM...
Page 88: ...Vers 111422 88 SPARE PARTS KDS NT70 KDS NT70 HM...