![Kollmorgen CARTRIDGE DDR Mounting Manual Download Page 5](http://html1.mh-extra.com/html/kollmorgen/cartridge-ddr/cartridge-ddr_mounting-manual_1990767005.webp)
5
Step 5: Secure Hardware for Run Configuration
1.
Remove Silver Hex Alignment
Screw from the hole labeled
“B” and secure it into the hole
labeled “A”.
C04x:
Use a 6mm hex bit and
torque to 9 N-m [80 lb-in].
C05x & C06x:
Use a 8mm
hex bit and torque to 18 N-m
[160 in-lb].
Check
Here
Step 6: Confirm Free Rotation
Torque specification in Step
5 must be followed to en-
sure IP-65 compliance!
1. Secure the Black, Phillips
Screw into the hole labeled
“B”. Torque the Phillips head
screw to 3.4 N-m [30 lb-in].
1.
Rotate shaft or load by hand
to ensure free rotation.
Congratulations!
Your Kollmorgen Cartridge DDR® motor
is ready for operation.
Small Frame Motor Removal Instructions
Step 1: Align Rotor
1.
Remove the Black Phillips Screw
from the hole labeled “B”
2.
Insert a 5 mm hex bit (C04X) or
6 mm hex bit (C05X/C06X) into
the hole labeled “B” and rotate
the shaft until the hex bit falls
into the alignment hole in the ro-
tor. Rotate shaft gently by hand.
Rotating the shaft under the
motor’s power or forcibly rotat
-
ing a large inertia may damage
the rotor hub, housing, or hex bit
when the bit drops into place.
3.
Remove the hex bit without ro
-
tating the shaft.
DDR Motor Mounting Guide | Step 5: Secure Hardware for Run Comfiguration