I/O Terminal /
MANUAL CONFIGURATION
30
Byte
Bit
Value
Description
GSE file
1
bin
Representation in Motorola format
(default)
0
bin
Standard-Bus mode slow FreeRun
(default) (see Standard-Bus cycle)
9
4
1
bin
Standard-Bus mode fast FreeRun
Standard
0
bin
WORD alignment inactive (default)
9
5
1
bin
WORD alignment active (see WORD
alignment)
Extended
0
bin
Standard-Bus mode is synchronous
(see Standard-Bus cycle)
9
6
1
bin
Standard-Bus mode FreeRun (default)
Standard
00
bin
Reaction to PROFIBUS error: Standard-
Bus cycle is abandoned (default, digital
outputs become 0, complex outputs are
set to a configured substitute value)
(see Reaction to PROFIBUS errors)
01
bin
Reaction to PROFIBUS error: Standard-
Bus outputs become 0
10
0-1
10
bin
Reaction to Standard-Bus error: DP
inputs remain unchanged
Standard
00
bin
Reaction to Standard-Bus error: DP
data exchange is abandoned (default)
(see Standard-Bus interruption)
01
bin
Reaction to Standard-Bus error: DP
inputs set to 0
10
2-3
10
bin
Reaction to Standard-Bus error: DP
inputs remain unchanged
Standard
11
3-6
X
Maximum length of the diagnostic data.
Allowed values: 16, 24, 32, 40, 48, 56,
64 (see Terminal diagnosis)
Extended
0
bin
If Standard-Bus mode is synchronous:
standard synchronous mode (default)
(see Standard-Bus cycle)
01
bin
If Standard-Bus mode is synchronous:
synchronous mode with optimized input
update (one cycle)
12
0-1
10
bin
If Standard-Bus mode is synchronous:
synchronous mode with optimized input
update (two cycles)
Extended
12
4-7
0
bin
Maximum DP buffer lengths not
changed
Extended