AKI2G-CDB-MOD-12T-000 | ADDITIONAL INSTALLATION TIPS

7.3

To Achieve Better EMC Protection

Initially, use the original cabling from Kollmorgen primarily.

Use shielded cables for RS232 communication.

Use twisted pair and shielded cabling for RS422 and RS485.

Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link, CAN, Device Net etc.

Install and connect according to applicable specifications for the relevant bus standard.

Use shielded cabling for Ethernet, preferably with foil and a braided shield.

D-sub covers should be shielded, and the shield should be connected to the cover 360° where
the cable enters.

Connect the shield at both ends.

Shielded cable

Not same potential

Ground plane 1

Ground plane 2

Ground plate

Ground plate in another building

0.1 

μ

F/250 V

With longer distances, there is a risk that the ground potential may be different. In that case, the shield
should only be connected at one end. A good alternative is to connect the other end of the shield to the
ground via a 0.1 µF/250 V plastic capacitor. Both ends are then connected to the ground in terms of
HF, but only connected to the ground at one end in terms of LF, thus avoiding the 50/60 Hz grounding
loops.

Metal cabinet

Metal cabinet

Terminal or connector

Terminal or connector

EMC cable gland

Plastic cable gland

Shielded cable

Short distance

Cable clamp
in steel

Shielded cable

1. Use an EMC cable gland or regular plastic cable gland, remove the outer jacket and connect the

shield to the installation plate with a 360° metal cable clamp.

2. Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC

in another. If the cables need to be crossed, cross them at 90° only. Avoid combining the cabling
for stronger 24 V DC outputs with the communication cabling.

Ferrite cores that are snapped onto the shielded cabling may remove minor disturbances. Large
ferrite pieces that are snapped onto unshielded cabling and where the wires go 2-4 times around the
cores are approximately 5-25 times more efficient.

ky

Kollmorgen | April 2017

23

Summary of Contents for AKI2G-CDB-MOD-12T-000

Page 1: ...rminal Installation Manual Edition A April2017 AKI2G CDB MOD 12T 00012 1 Touchscreen HMI Keep all manuals as a product component during the life span of the product Pass all manuals to future users ow...

Page 2: ...ithout prior notice Printed in the United States of America This document is the intellectual property of Kollmorgen All rights reserved No part of this work may be reproduced in any form by photocopy...

Page 3: ...3 2 2 Other Connections and Peripherals 11 4 Technical Data 5 Chemical Resistance 5 1 Metal Casing 14 5 2 Touch Screen and Overlay Material 15 5 2 1 Autoflex EBA 180L 15 5 2 2 Touch Screen Surface fo...

Page 4: ...o understand and use Configuration is carried out on a PC using the Kollmorgen Visualization Builder configuration tool The project can then be transferred and stored in the operator panel itself Vari...

Page 5: ...d the eye open flush with plenty of water and get medical attention The figures in this manual serve an illustrative purpose Because of the many variables associated with any particular installation t...

Page 6: ...pproved expansion units are allowed to be connected to the port designated EXPANSION At the moment there are no such units evaluated or allowed SEULES LES UNIT S D EXTENSION CERTIFI ES UL ET cUL PEUVE...

Page 7: ...fields no direct sunlight no large sudden temperature changes Install the HMI panel according to the accompanying installation instructions Ground the HMI panel according to the accompanying installat...

Page 8: ...ng to local regulations The following components contain substances that might be hazardous to health and the environment lithium battery electrolytic capacitor and display 2 8 Appearance ofAir inTouc...

Page 9: ...late thickness 12 8 mm The following drawings show the space requirements in millimeters when installing the operator panel The drawings are only illustrative and may be out of proportion 3 1 1 AKI2G...

Page 10: ...e the cut out dimensions in the outline drawing For more information see sections Operator Panel Drawings and Technical Data 3 Install the HMI panel into the cutout 4 Secure the HMI panel in position...

Page 11: ...net C Figure 3 2 The image is illustrative only and may differ slightly from the actual panel Connect cable A Connect cable B using an M5 screw and a grounding conductor as short as possible that is s...

Page 12: ...wder coated aluminum Frame material Powder coated aluminum Weight 2 6 kg CPU i MX6DualLite Dual Cortex A9 1 0 GHz 512 kB L2 cache Serial port for COM1 RS232 COM2 RS422 RS485 and COM3 RS485 9 pin D sub...

Page 13: ...H 261 1 x 163 2 mm Pixel errors Class I ISO 9241 307 Backlight brightness 400 cd m2 Backlight lifetime 50 000 hours Operating temperature 10 C to 60 C Storage temperature 20 C to 70 C Relative humidi...

Page 14: ...nce to the following chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Sodium hypochlorite 10 Turpentine Note If exposure to a...

Page 15: ...c soda 40 1 Methanol Trichloroacetic acid 50 Cutting oil Nitric acid 10 White Spirit Cyclohexanol Paraffin oil Windex 1 Diacetone alcohol Persil powder in solution 1 1 Extremely faint glossing of the...

Page 16: ...2 3 TouchScreenProtector For harsh environments and exposure to outdoor conditions it is recommended to use a protective film to guard the touch screen from damage This optional part can be ordered f...

Page 17: ...nnectors Figure 6 1 AKI2G CDB MOD 12T 000 Pos Connector Description 1 Power supply 24 V DC 18 32 V DC 2 USB USB Host 2 0 max output current 500 mA 3 LAN A 10 100 Base T shielded RJ45 4 LAN B 10 100 Ba...

Page 18: ...TxD 4 RS422 Rx RS485 Tx Rx 5 GND GND 6 RS422 Tx RS485 Tx Rx 7 RS232 RTS 8 RS232 CTS 9 RS422 Rx RS485 Tx Rx Note In order to utilize two communication ports the Y split cable CAB109 must be used In ord...

Page 19: ...L DRAWINGS 6 3 Digital Outputs Ratings Maximum supply voltage 32 0V DC 22Vrms AC Maximum load current 0 5A DC 0 5Arms AC Isolation Channel to Channel 1000V DC 550Vrms AC Channel to System 1000V DC 550...

Page 20: ...AKI2G CDB MOD 12T 000 OPERATOR PANEL DRAWINGS 6 4 AKI2G CDB MOD 12T 000Outline Figure 6 2 AKI2G CDB MOD 12T 000 ky Kollmorgen April 2017 20...

Page 21: ...ectly according to local electrical codes between the chassis of the HMI panel and the closest grounding point on the door see 3 in drawing above 3 Connect a strong but short grounding braid between t...

Page 22: ...ther Ethernet unit has its shield directly grounded or grounded via a capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at bothends is inappropriate Hum or grounding...

Page 23: ...ternative is to connect the other end of the shield to the ground via a 0 1 F 250 V plastic capacitor Both ends are then connected to the ground in terms of HF but only connected to the ground at one...

Page 24: ...acitor is cut in half with an 8 10 C increase in temperature A 15 20 C temperature increase results in a quarter of the lifespan etc Rittal has a good program for estimating the anticipated average te...

Page 25: ...re for example SELV according to EN 60950 protection against electric shock and UL 950 Note Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with...

Page 26: ...n for example a USB memory stick keyboard or similar device is plugged in If a number of units are connected that have a 0 V and a ground connection and these are connected to various grounding points...

Page 27: ...he shield must be grounded at one end The other end is usually grounded but with longer distances or when there is a difference in the ground potential the shield should be connected to the ground via...

Page 28: ...20 seconds 3 Enter a PIN code if the service menu is password protected 4 The touch calibration screen displays the following message Tap anywhere on screen or touch calibrate will start in 10 second...

Page 29: ...the X32 port and any combination can be active simultaneously When incorporating an AKI HMI panel into a KAS IDE Project variables that are planned to be used inside the KVB software are designated by...

Page 30: ...red into KVB when it is opened from inside the KAS IDE KAS IDE KVB Additionally the PxMM s IP address is also transferred into the KVB project when it is opened from within the KAS IDE To open KVB fro...

Page 31: ...Template Project some of the template projects will contain a KVB Project Double clicking on it will also launch KVB In this scenario tags and the target IP address are imported into KVB but the AKI P...

Page 32: ...ge base for answers get downloads and suggest improvements North America Europe KOLLMORGEN KOLLMORGEN Europe GmbH 203A West Rock Road Pempelfurtstra e 1 Radford VA 24141 USA 40880 Ratingen Germany Web...

Reviews: