AKI2G-CDB-MOD-12T-000 | INSTALLATION
3.2
Installation Process
The following is needed:
•
A Phillips/slot screwdriver
1. Unpack and check the delivery. If damage is found, notify the supplier.
Note:
Place the HMI panel on a stable surface during installation.
Dropping the HMI panel or letting it fall may cause damage.
2. To cut a correct opening for the HMI panel, use the cut out dimensions in the outline drawing. For
more information, see sections
Operator Panel Drawings
and
Technical Data
.
3. Install the HMI panel into the cutout.
4. Secure the HMI panel in position by screwing the slotted thumb screw clockwise, allowing the
built-in bracket to flip out and tighten against the cabinet.
Figure 3-1:
Tighten the screws to 0.7 Nm ± 0.2 Nm.
5. In cases where the front panel seal (IP54 or greater, NEMA-4X) is critical, use a torque wrench to
ensure all screws are torqued within the specification above.
ky
Kollmorgen | April 2017
10