6.7 Connectors
Given voltage and current data are the lowest values allowed by UL and CE.
Connector
Type
Max. Cross Section
Current
Voltage*
Hybrid IN, X1
Hybrid Connector
(male), 7 poles
4 x 0.34mm², 22 awg
3 x 2.5 mm², 14 awg
0.5 A
18 A
30 V
850 V
Hybrid OUT, X2
Hybrid Connector
(female), 7 poles
4 x 0.34mm², 22 awg
3 x 2.5 mm², 14 awg
0.5 A
18 A
30 V
850 V
Digital I/O, X3
Connector (female),
8 poles
8 x 0.34 mm², 22 awg
2 A
30 V
Motor, X4
Connector (female),
8 poles
4 x 2.5 mm², 14 awg
4 x 1.0 mm², 18 awg
15 A
10 A
630 V
30 V
Feedback X5
Connector (male),
17 poles
17 x 0.75 mm², 20 awg
3.6 A
63 V
STO/Fieldbus, X6 Connector (female),
4 poles
4 x 0.34 mm², 22 awg
1 A
50 V
* Rated voltage with pollution level 2, use Kollmorgen cables only.
6.8 Cable Requirements
For information on the chemical, mechanical, and electrical characteristics of the cables
please refer to the accessories manual or contact customer support.
Use Kollmorgen hybrid, motor, and feedback cables only. You will loss system warranty, if
you use hybrid, motor or feedback cables from a manufacturer other than Kollmorgen.
Cable from
Cable type
Cable to
Cross
section
AKD-C X20/X21
CCNCN1-025
1)
AKD-N X1, hybrid
3 x 2.5 mm²
4 x 0.25 mm²
AKD-N X2
CCNNN1-025
1)
AKD-N X1, hybrid
3 x 2.5 mm²
4 x 0.25 mm²
AKD-N X3
Phoenix SAC-
8P-M12MS
2)
Digital I/O
8 x 0.25 mm²
AKD-N-DB/DS/DF X4 CCJNA1-015
1)
Motor Power with brake and
Hiperface DSL feedback,
hybrid
4 x 1.5 mm²
2 x 0.75 mm²
2 x 0.34 mm²
AKD-N-DS/DF X4
CM0NA1-015
1)
Motor Power without brake
4 x 1.5 mm²
AKD-N-DS/DF X4
CM1NA1-015
1)
Motor Power with brake
4 x 1.5 mm²
2 x 0.75 mm²
AKD-N-DS/DF X5
CFSNA1-002
1)
Motor Feedback SFD
4 x 2 x 0.25 mm²
AKD-N-DS/DF X5
CFCNA1-002
1)
Motor Feedback Comcoder
7 x 2 x 0.25 mm²
AKD-N-DS/DF X5
CFENA1-002
1)
Motor Feedback EnDat/BiSS
7 x 2 x 0.25 mm²
AKD-N-DS/DF X5
CFHNA1-002
1)
Motor Feedback Hiperface
7 x 2 x 0.25 mm²
AKD-N-DF X6
Phoenix NBC-
MSD/5,0-93E
2)
Tertiary Fieldbus
2 x 2 x 0.14 mm²
AKD-N-DS X6
Phoenix SAC-
4P-M12MS
2)
Single Drive STO switch
4 x 0.34 mm²
1)
Followed by length coding. Contact your Kollmorgen sales representative.
2)
Example, similar cables are available from other distributors.
AKD-N Installation | 6 Technical description and data
Kollmorgen | December 2014
25