AKD-N Installation | 8 Electrical Installation
8.7.2 Digital Output
The drive supplies one programmable digital output and the permanent STO-Status output for
drives with "DS" option. For the programmable output choose the required function in the
setup software. Messages from pre-programmed functions stored in the drive can be output
here. A list of these pre-programmed functions can be found in the setup software. If an out-
put is to be assigned to a pre-programmed function, then the parameter set must be saved in
the drive. By default,the output is not programmed (off). For more information refer to the
setup software.
Technical characteristics:
l
STO-Status signal is available for AKD-N with option "DS" only.
l
24 V , 20 VDC to 30 VDC
l
All digital outputs are floating, max.100 mA
l
Can be wired as active low or active high (see examples below)
l
Update rate: 250 µs
Wiring diagram:
56