3 Approvals

3.1 Conformance with UL/cUL

This device is listed under UL (Underwriters Laboratories Inc.) file number

E217428

.

UL Markings / Marquages UL

English

Français

This product is suitable for use on a circuit cap-
able of delivering not more than 42,000 rms sym-
metrical amperes, 480 V maximum.

Ce produit est conçu pour une utilisation sur un circuit
capable de fournir 42.000 ampères symétriques (rms)
maximum pour 480 V maximum.

Maximum surrounding air temperature 40°C.

La température maximale de l'air ambiant de 40°C.

AKD-C are intended to be used in a pollution
degree 2 environment.

AKD-C sont prévus pour une utilisation dans un
environnement de pollution de niveau 2.

AKD-C : Use 60/75°C copper wire only.

AKD-C: Utilisez seulement un fil cuivre 60/75°C.

AKD-C :

CAUTION Risk of Electrical Shock!

Capacitors can have dangerous voltages present
up to 7 minutes after switching off the supply
power. For increased safety, measure the
voltage in the DC bus link and wait until the
voltage is below 50 V.

AKD-C :

ATTENTION: Risque de choc électrique!

Des tensions dangereuses peuvent persister dans les
condensateurs jusqu'à 7 minutes après la mise hors
tension. Pour plus de sécurité, mesurez la tension
dans la liaison de bus CC et attendez qu'elle soit
inférieure à 50 V.

For use in Canada:
Transient surge suppression shall be installed on
the line side of this equipment and shall be rated
277 V (phase to ground), 480 V (phase to phase),
suitable for overvoltage category III, and shall
provide protection for a rated impulse withstand
voltage peak of 2 kV.

Pour utilisation au Canada:
Suppression de surtension transitoire doit être installé
sur le côté de la ligne de ce matériel et doit être évalué
277 V (phase à terre) , 480 V (entre phases) , adapté à
la catégorie de surtension III , et doit fournir une pro-
tection pour un choc nominale supporter la tension de
crête de 2 kV.

The following fuse types are recommended for branch circuit protection for AKD-C01007-CBXX:

Les types de fusibles suivants sont recommandés pour protection de secteur pour AKD-C01007-CBXX:

Model/

Modèle

Class/

Classe

Voltage Rating/

Niveau de tension

Max. Fuse&SCC Rating/

Niveau maximum & SCC

Nonrenewable Cartridge fuse CC, J

600 VAC

20 A, 200 kA

The following table illustrates the torque requirements for the field wiring connectors :

Le tableau suivant indique les spécifications de couple pour les connecteurs de câblage sur site:

Model/

Modèle

Torque/

Couple serrage

, LB IN (Nm)

Wire size/

Section de fil

, AWG (mm²)

AKD-C X12

6.2 - 7.1 (0.7 - 0.8)

12 - 8 (4 - 10)

AKD-C X20A

6.2 - 7.1 (0.7 - 0.8)

12 - 8 (4 - 10)

AKD-C X21A

6.2 - 7.1 (0.7 - 0.8)

12 - 8 (4 - 10)

AKD-C X14

6.2 - 7.1 (0.7 - 0.8)

12 - 8 (4 - 10)

AKD-C X13

1.8 - 2.2 (0.2 - 0.25)

14 - 12 (2.5 - 4)

AKD-C X15

1.8 - 2.2 (0.2 - 0.25)

20 - 18 (0.5 - 0.8)

AKD-C X16

1.8 - 2.2 (0.2 - 0.25)

20 - 18 (0.5 - 0.8)

Split gage of AKD-N screwed connectors: max. 2.8 mm.

Le gage de split des connecteurs vissé d'AKD-N: 2,8 mm max.

Cold plate for AKD-N: at 40°C surrounding air temperature and 680 VDC supply voltage:

Plaque froide pour AKD-N: à température ambiante 40°C et tension d'alimentation 680 VDC:

- AKD-N00307: 240 mm x 240 mm x 10 mm or equivalent (LxWxT, Aluminum cold plate, uncoated)
- AKD-N00607: 500 mm x 500 mm x 10 mm or equivalent (LxWxT, Aluminum cold plate, uncoated)
- AKD-N01207: 480 mm x 400 mm x 84 mm or equivalent (LxWxT, 31 vertical fins, Aluminum heat sink,
uncoated)

AKD-C/N Safety Notes | 3   Approvals

Kollmorgen | kdn.kollmorgen.com | March 2021

23

Summary of Contents for AKD-C Series

Page 1: ...www kollmorgen com en us products drives servo akd n Safety Notes Edition A March 2021 Part Number 903 200021 99 For safe and proper use follow these instructions Keep for future use For environmental...

Page 2: ...ebHelp format Describes how to use your devices in common applications It also provides tips for maximizing your sys tem performance with the AKD C and AKD N The online help includes the Parameter and...

Page 3: ...D N 8 1 1 6 Warning notes placed on the product 9 1 2 Product life cycle handling 10 1 2 1 Transport 10 1 2 2 Packaging 10 1 2 3 Storage 10 1 2 4 Installation setup and normal operation 11 1 2 5 Decom...

Page 4: ...Number of the product see product label This number is the link between your product and the manual The product Hardware Revision Number must match the Hardware Revision Number on the cover page of t...

Page 5: ...upply side of AKD C Lethal voltages The equipment produces high electric voltages up to 900V Do not open or touch the equip ment during operation Keep all covers closed During operation AKD C may have...

Page 6: ...t at 400 V and 480 V For the cases of group installations and of DC powered drives AKD has not been evaluated by Kollmorgen UL or T V for group installations nor are rat ings defined for DC input volt...

Page 7: ...external regen resistor contacts in applications with any short circuits to the DC Bus link contacts The use of the device in the following environments is also prohibited potentially explosive areas...

Page 8: ...of hybrid cables for connecting AKD N and AKD C devices For connecting AKD N to MKD C devices use MKC HYB z AKN cable only Power supply AKD N series drives must be powered by AKD C or MKD C intellige...

Page 9: ...egulations for high protective earthing conductor current CAUTION Risk of minor burns During operation the heat sink of the drive may reach temperatures above 80 C 176 F Before touching the device che...

Page 10: ...damage Inform the shipper and the manufacturer of any damage to the package or product 1 2 2 Packaging The packaging consists of recyclable cardboard with inserts and a label on the outside of the bo...

Page 11: ...t liquid enters the device The inside of the unit can only be cleaned by the manufacturer Opening the device voids the warranty To clean the device exterior 1 Decommission the device see chapter 1 2 5...

Page 12: ...Exchange of other drive system parts If parts of the drive system for example cables must be replaced proceed as follows 1 Decommission the device see chapter 1 2 5 Decommissioning 2 Exchange the part...

Page 13: ...estimmungsgem e Verwendung AKD N 18 2 1 6 Warnhinweise auf dem Produkt 19 2 2 Produkt Lebenszyklus Handhabung 20 2 2 1 Transport 20 2 2 2 Verpackung 20 2 2 3 Lagerung 20 2 2 4 Installation Setup und N...

Page 14: ...d Die Nummer ist die Verkn pfung zwischen dem Produkt und dem Handbuch Diese Revisionsnummer muss mit der Hardware Revisionsnummer auf dem Deckblatt der Betriebsanleitung bereinstimmen Technische Date...

Page 15: ...en bis zu 900 V ffnen oder ber hren Sie die Ger te w hrend des Betriebs nicht Halten Sie w hrend des Betriebs alle Abdeckungen und Schaltschrankt ren geschlossen W hrend des Betriebes kann der AKD C s...

Page 16: ...triebe Der AKD wurde weder von Kollmorgen UL noch dem T V f r Gruppeninstallation unter sucht Es sind keine Werte f r eine DC Spannungsversorgung definiert Gruppeninstallationen m ssen in Bezug auf ve...

Page 17: ...m igen Kurzschl ssen der Anschl sse des Bremswiderstandes in Anwendungen mit Kurzschl ssen der DC DC Zwischenkreisanschl sse Die Verwendung des Ger tes in den folgenden Umgebungen ist ebenfalls unters...

Page 18: ...ss der AKD N an MKD C Ger te nur mit MKC HYB z AKN Kabeln Spannungsversorgung AKD N Servoverst rker m ssen von den intelligenten AKD C oder MKD C Netzteilen mit einer Gleichspannung von 55 VDC bis 800...

Page 19: ...ture and wait until it has cooled below 40 C 104 F bersetzung Nach Abschalten 7 Minuten bis zur Wartung abwarten bersetzung Die Mindestquerschnitt des Schutzleiters muss den lokalen Sich erheitsbestim...

Page 20: ...nformieren Sie Spediteur und Hersteller ber Sch den an der Verpackung oder am Produkt 2 2 2 Verpackung Die Verpackung besteht aus recyclingf higem Karton mit Eins tzen und einem Aufkleber auf der Au e...

Page 21: ...nach der Reinigung mindestens 30 Minuten bevor Sie das Ger t wieder in Betrieb nehmen 3 Schutzgitter am L fter Mit einer trockenen B rste reinigen 2 2 6 Au er Betrieb nehmen Nur Fachpersonal mit Kennt...

Page 22: ...ger Teile des Antriebssystems Wenn Teile des Antriebssystems ausgetauscht werden m ssen zum Beispiel Kabel gehen Sie wie folgt vor 1 Nehmen Sie das Ger t au er Betrieb siehe Kapitel 2 2 6 Au er Betrie...

Page 23: ...ression de surtension transitoire doit tre install sur le c t de la ligne de ce mat riel et doit tre valu 277 V phase terre 480 V entre phases adapt la cat gorie de surtension III et doit fournir une...

Page 24: ...The AKD C N meet the noise immunity requirements to the 2nd environmental category industrial environment For noise emission the AKD C N meet the requirement to a product of the Category C2 These devi...

Page 25: ...U with delegated directive 2015 863 EU for installation into a machine 3 6 Conformance with EAC EAC is the abbreviation for Eurasian Conformity The mark is used in the states of the Eur asian Customs...

Page 26: ...ers M23 The M23 connector covers are required for protecting X2 of the last AKD N in the strings Spare parts Spare parts are described in the regional accessories manual Connector Kit X12 16 Shield cl...

Page 27: ...the last AKD N in a string is part of the AKD C delivery package Spare parts Spare parts are described in the regional accessories manual Mounting clamps set Sealing plug set for connectors Part Numb...

Page 28: ...ers get downloads and suggest improve ments North America KOLLMORGEN 201 West Rock Road Radford VA 24141 USA Web www kollmorgen com Mail support kollmorgen com Tel 1 540 633 3545 Fax 1 540 639 4162 Eu...

Reviews: