10
4. Caring for the Model
(1) Remove the air from the amnion before storing.
To remove air, open the two-way stopcock, and twist the valve on the rubber bladder
counterclockwise to loosen it.
(2) Wrap the abdominal wall piece in the abdominal wall protective sheet provided as an
accessory, then place it back on the main body and place the skin over the top to store.
*1. The abdominal wall protective sheet prevents the oil component from oozing out of the
abdominal wall piece to the skin and other parts.
*2. If the oil component contained in the abdominal wall piece oozes out to the skin and
other parts, it will promote deterioration of the product. Be sure to wrap the abdominal
wall piece in the abdominal wall protective sheet for storage.
*3. If the abdominal wall piece becomes sticky, apply the baby powder provided as an
accessory generously to the piece.
(3) If the model becomes dirty, wipe it with a moist gauze or similar soft material using a neutral
solvent diluted with water.
*Do not clean it with rubbing alcohol, thinners, benzene, or other organic solvents.
(4) Place the model in the proper orientation when storing to prevent deformation.
(5) Storing the model for an extended time in a high or low temperature environment, or under
exposure to direct sunlight, may cause the oil component in the abdominal wall piece to ooze
out, causing deformation or discoloration of the model. If possible, store the model at 10-30°C,
away from direct sunlight.
(6) Place the model in the storage bag provided as an accessory when storing.