8.1

Operating conditions

The stated outputs of the units are obtained under the reference conditions outlined in ISO 8528-1(2005):
Total barometric pressure: 100 kPa - Ambient air temperature: 25°C (298 K) - Relative humidity: 30%.
The unit's output is reduced by approximately 4% for every additional 10°C and/or approximately 1% for every additional 100m in 
altitude. Units can only operate while stationary.

8.2

Capacity of the generating set

Before  connecting  and  operating  the  unit,  calculate  the  electrical  power  required  by  the  units  to  be  used  (in  watts)*.  To  ensure 
optimal operation, the total wattage of all equipment used at the same time must be:

-

greater than 60% of the rated load for the unit (risk of insufficient load);

-

less than the rated load for the unit during continuous operation (risk of overload).

If the unit is run under or over its rated load frequently or for long periods of time, it can start to wear very quickly. Damage caused 
in this way will not be covered by the warranty.

*

This load is usually indicated in the technical specifications or on the manufacturer's plate for the equipment. Some equipment requires a higher 

load when starting. This minimum required power must not exceed the unit's maximum power

.

8.3

Generating set identification

The identification plate for the unit (example shown below) is affixed inside one of the skirts or on the chassis.

(A):

Model

(B):

CE/EAC marking

(C):

Guaranteed  acoustic 
power level

(D):

Maximum power

(E):

Nominal power

(F):

Power factor

(G):

Ground

(H):

Current amperage

(I):

Current frequency

(J):

Current voltage

(K):

Protection rating

(L):

Reference standard

(M): Serial number

Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and 
engine serial numbers below. 

Unit serial number:

Engine manufacturer:

(e.g. 

Kohler)

Engine serial number:

 (e.g Kohler (SERIAL 

NO. 4001200908))

……/………….. - ……..………..….…. - ………

……..……..………..….…..….

……..………..….….……..………..….….

8.4

Specifications

Model

TECHNIC 6500 A AVR UK C5

Maximum power

6300 W

Rated output

5200 W

Acoustic pressure at 1 m

83 dB(A)

Measurement uncertainty

0,4 dB(A)

Engine type

CH440E_C5

Maintenance kit

RKS2

Recommended fuel 

Unleaded petrol

Fuel tank capacity

18 L

Recommended oil

10W30

Oil sump capacity

1,29 L

Oil cut-out*

O

Direct current

X

Alternating current

230V - 22,6A

Circuit breaker(s)**

O

Socket type

2x1P+T 115V 16/32A - 2x1P+T 230V 16/32A

Spark plug type

330830012

Dimensions l x w x h 

81 x 55,5 x 59 cm

Weight (without fuel)

101 kg

o: standard

X: not available

*Oil cut-out: If there is no oil in the engine sump or if the oil pressure is low, the oil cut-out mechanism automatically stops the engine to prevent any 
damage. If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
**Circuit breaker: The generating set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the 
event of an overload and/or short circuit, the supply of electrical energy may be cut. If necessary, replace the circuit breakers in the generating set 
with circuit breakers with identical nominal ratings and specifications.

8.5

Authorised fuel

Using fuel which does not comply with the following specifications exposes the equipment to irreversible damage not covered under 
warranty: 

-

Cleanliness and quality: ensure that the petrol used does not contain water and that it is fresh and clean (not out of date or 
contaminated). For the 

-

Octane rating: minimum octane rating of 87 (R+M)/2 or minimum octane rating of 90 (RON = Research Octane Number)

-

Blends: the use of unleaded petrol containing up to 10% ethyl alcohol is authorised (France: SP95-E10). It is not permitted 
to use unleaded petrol containing less than 90% petrol, e.g. E15, E20 or E85. Blends of methyl tert-butyl ether (MTBE) and 
unleaded petrol are approved (up to a maximum of 15% MTBE by volume).

However, it is strongly recommended that the same type of fuel is used throughout the complete service life of the unit. If the unit is 
used infrequently (less than once a month), use new fuel with each use or add a stabilizing additive to the fuel tank.

8.6

EU Declaration of Conformity

(G)

(B)

(C)

(D)

(E)

(F)

(I)

(H)

(J)

(K)

(L)

(M)

(A)

21/24

Summary of Contents for SDMO Technic 6500 A AVR UK C5

Page 1: ...33522200401_2_1 11 2019 Manuel d utilisation et d entretien Notice originale Instruction and maintenance manual Translation of the original note TECHNIC 6500 A AVR UK C5...

Page 2: ...A 1 3 14 7 18 6 16 17 5 4 10 6 9 8 13 23 12 12 20 21 19 19 11 22 15 24 2 25 26...

Page 3: ...B C 3 1 2 4 5 2 5 1 4 8 7 6 3...

Page 4: ...D E F FRANCE 0 806 800 107 Prix appel 5 1 2 6 3 4 1 3 2 2 1...

Page 5: ...on des personnes Les consignes et r gles de s curit sont lire attentivement et respecter imp rativement pour ne pas mettre en danger la vie ou la sant des personnes En cas de doute sur la compr hensio...

Page 6: ...ler un appareil les mains ou les pieds humides Ne jamais exposer le mat riel des projections de liquide ou aux intemp ries ni le poser sur un sol mouill 2 7 1 Installation temporaire ou semi permanent...

Page 7: ...ition DANGER RISQUE DE PERTE D AUDITION Lors du fonctionnement de l appareil porter imp rativement des protections auditives adapt es 2 9 Risques lors des op rations de manutention d utilisation et d...

Page 8: ...du mat riel et la totalit de la commande 2 Si l appareil est muni d une bride de transport la retirer La bride de transport est une plaque m tallique situ e sous le moteur pr s de la borne de mise la...

Page 9: ...ifier visuellement le niveau de carburant sur l indicateur A5 la palette rouge de l indicateur doit se situer entre le niveau maximum de carburant F Full plein et le niveau minimum de carburant E Empt...

Page 10: ...s conditions d utilisation de l appareil et des besoins Effectuer les entretiens aux ch ances calendaires indiqu es m me si le nombre d heures de fonctionnement n est pas atteint La garantie est notam...

Page 11: ...uvercle du filtre air et le verrouiller 5 3 5 Nettoyer le pare tincelles 1 Sur le silencieux d chappement d visser la vis de fixation du pare tincelles E2 2 D poser le pare tincelles A25 E1 3 A l aide...

Page 12: ...moteur neuve 7 Remettre en place une bougie d allumage neuve 8 Tirer plusieurs fois la poign e du lanceur r enrouleur A24 pour r partir l huile dans le cylindre Remiser l appareil 9 Nettoyer l appare...

Page 13: ...er Bluetooth GSC101 lorsque l alerte s affiche dans l application Generator Smart Care environ tous les deux ans 1 A l aide d un petit tournevis cruciforme ouvrir le couvercle du bo tier 2 Retirer les...

Page 14: ...rr te automatiquement le moteur pour pr venir tout endommagement Dans ce cas v rifier le niveau d huile moteur et faire l appoint si n cessaire avant de proc der la recherche d une autre cause de pann...

Page 15: ...e nombre d heure de fonctionnement prendre en compte est de 8 heures par jour CONDITIONS D APPLICATION DE LA GARANTIE La garantie d bute compter de la date d achat de l appareil par le premier utilisa...

Page 16: ...tre appareil durant les 6 mois suivant la d livrance du bien Ce d lai est port 24 mois compter du 18 mars 2016 sauf pour les biens d occasion La garantie l gale de conformit s applique ind pendamment...

Page 17: ...aterial damage 2 Instructions and safety regulations personal protection The instructions and safety regulations must be read carefully and followed to avoid endangering personal health and safety If...

Page 18: ...e ou semi permanente chantier spectacle activit A If the unit is not equipped with an integrated differential protection device at delivery standard version with insulated neutral on the unit s earth...

Page 19: ...ng handling operations use and maintenance For safety reasons all operations must be carried out by staff with the necessary skills and using suitable equipment Maintenance must be carried out on a re...

Page 20: ...th the positive terminal Observe the polarity of the battery terminals when connecting it as this could cause serious damage to the electrical equipment Some units require a running in period Contact...

Page 21: ...performs 6 starting attempts If the generating set does not start after these 6 attempts see the section on Resolving minor faults The APM202 automatically performs 6 starting attempts If the generat...

Page 22: ...d regularly check the level The oil level must be between the minimum and maximum marks on the dipstick If the oil level is too low keep topping it up If the oil level is too high drain some off 4 Ref...

Page 23: ...nd sudden movements should be avoided Ensure that the place where it is to be stored or used is carefully prepared beforehand Before any fixed installation on a trailer or inside a vehicle consult one...

Page 24: ...ition and correctly connected NO Check the spark plug s YES The devices to be used have not been connected prior to starting NO Disconnect the devices then try to restart the generating set YES The AP...

Page 25: ...Acoustic pressure at 1 m 83 dB A Measurement uncertainty 0 4 dB A Engine type CH440E_C5 Maintenance kit RKS2 Recommended fuel Unleaded petrol Fuel tank capacity 18 L Recommended oil 10W30 Oil sump cap...

Page 26: ...14 in application of the harmonized standards EN 60034 1 2010 COR 2010 EN 61000 6 1 2007 EN 61000 6 2 2005 COR 2005 EN 61000 6 3 2007 AMD1 2011 AMD1 COR 12 EN 55011 2009 AMD 1 2010 Relating to the res...

Page 27: ...arising out of material damage which includes but is not limited to the following Any operating losses costs or expenses resulting from unavailability of the unit etc The warranty is limited to the c...

Page 28: ...f the latter under the terms of the contract or when carried out under its responsibility Article L211 5 To comply with the contract the goods must 1 Be suitable for the use customarily expected of si...