6
1.
Run the supply cable through the Mounting Bracket.
Note!
The cable through the Mounting Bracket must be routed through Plastic
Conduit of suitable diameter (not supplied). The Plastic Conduit must be
securely fixed.
2.
Make the connection between the 2 core cable and the Rada Pulse Control
Box using the plug-in connector (supplied).
Refer to the Rada Electronic Washroom Product Manual for instructions.
3.
The Shower Panel must be earthed by connecting the earth conductor to the
Earth Terminal inside the Panel.
Supplementary bonding
: within the shower room, all accessible conductive
parts of electrical equipment and extraneous conductive parts (metal parts) that
are likely to introduce earth potential, must be electrically bonded to earth using
a minimum cable size of 4.0 mm² if the cable is not mechanically protected,
(2.5 mm² if mechanically protected).
Rada PA ETF / PA ETFW Panels Only
Plastic Conduit
(not supplied)
Earth Terminal
Supply Pipe