The following safety measures must be observed:
• The disinfection process is not to be initiated unless adequate systems
are in place to ensure that the area is clear of any persons prior to and
during the disinfection process.
For this reason, the cycle can only be triggered
15 minutes
after the Mixer Valve was last activated.
•
A PIR sensor connected to the Sensor Box must be used to detect the presence
of any person in the affected area. Make sure it is fit for purpose according to the
expected humidity levels during the Thermal Disinfection cycle. This will depend
upon the size of washroom, the PIR position and the number of outlets used.
•
The PIR system should be checked to ensure that the appropriate area is covered
adequately and that the disinfection process can be aborted successfully.
•
The operation of the PIR should be checked regularly and just before each
disinfection cycle.
Please consult the national or local authority Legionella Legislation or Guidelines
as appropriate for your country/area to see how the Thermal Disinfection process
can be used to meet the required level of hygiene.
The disinfection cycle and its settings are controlled in the
“Disinfection”
and
“Disinfection Setup”
screens. Disinfection is enabled or disabled in the
“Outlet
Setup”
screen.