background image

12

1128227-A01-D   Date: 13/8/2010 

B. Control Switch Operation

M. Drilling And Cutting Acrylic

DRILLING:

 Small holes can be drilled with a twist drill, 

but the cutting edge MUST be backed off with an oil 

stone (the sharp edge dulled). Large holes must be 

drilled with a hole saw. Maximum drill size-12mm. Drill 

speeds-6mmx1800 RPM-12mmx900 RPM.

NOTE:

 Always drill from acrylic surface.

CUTTING:

 If for any reason the acrylic requires cutting,  

should happen to be damaged, it can be restored by 

polishing with an abrasive cleaner. Deep scratches 

can be removed by rubbing with 600 grade wet & dry 

sandpaper then polishing.

N. Clean-Up After Installation

•  Clean the area around the blower motor of all dust 

and debris.

•  Use warm water and a liquid detergent to clean the 

surface of the bath with airjets.  

Do not use abrasive 

cleaners

, as they may scratch and dull the surface. 

Do not use powdered cleaners unless the cleaner 

is fully dissolved in water.

 Solid substances 

could block the airjets. 

Do not use bleach or 

ammonia cleaning solutions.

 Chemically active 

cleaning solutions can damage the bath surface. 

Refer to the homeowners guide for normal cleaning 

recommendations.

BATH OPERATION

A. Fill the Bath

CAUTION: Risk of product damage.

 Ensure 

that the area around the blower motor is free 

of sawdust, insulation, dirt, or other small loose 

debris. Such material could clog the blower  

blower motor.

NOTE:

 Please read these steps carefully before 

you operate your bath with airjets. Troubleshoot any 

problems using the “Troubleshooting” section.

��������������������

Push 1 = blower on  

Push 2 = blower off

�������������������������������������������������������������������������������������������������

C. Preliminary Checks

•  Temporarily remove all access panels.

•  Verify that the union connection at the check valve is 

securely hand tightened.

•  Verify that the blower motor is securely installed.

•  Verify that the swtich tube is securely connected at 

the air switch and at the blower motor.

•  Fill the bath to a level at least 50mm above the top of 

the highest airjet.

Summary of Contents for OVE RECT drop in 1709A-GAB-0

Page 1: ...10 A 50Hz C Installation Read the entire installation instructions before beginning the installation BEFORE YOU BEGIN BUBBLE MASSAGE BATH INSTALLATION INSTRUCTIONS 1128227 A01 D Date 13 8 2010 Blower...

Page 2: ...2 REGATTA BUBBLE MASSAGE 11303A GAB 0 1128227 A01 D Date 13 8 2010 OVE BUBBLE MASSAGE 1709A GAB 0 50...

Page 3: ...3 1128227 A01 D Date 13 8 2010 EVOK BUBBLE MASSAGE 18263A GAB 0 EVOK RECT FREESTANDING BUBBLE MASSAGE 18344A GAB 0 50 837 5 1675 762 408 5 50 36 513 610 81...

Page 4: ...4 1128227 A01 D Date 13 8 2010 EVOK OVAL BUBBLE MASSAGE 18346A GAB 0 EVOK OVAL FREESTANDING BUBBLE MASSAGE 18348A GAB 0 398 750 50 1700 850 39 50 510 610 398 750 50 1700 850 50 530...

Page 5: ...5 ESCALE DROP IN BUBBLE MASSAGE BATH 11343A GAB 0 1128227 A01 D Date 13 8 2010 ESCALE FREESTANDING BUBBLE MASSAGE BATH 11344A GAB 0...

Page 6: ...or property damage Please read all instructions thoroughly before beginning installation including the following Product Requirements WARNING Keep the area around the blower motor clean and free of de...

Page 7: ...g Install an access panel to allow the pump to be serviced Bath may be installed next to the Bath rim must be fully supported wall or as an island installation Tile Brick or timber B Whirlpool Area Co...

Page 8: ...TALL THE BATH CAUTION Risk of product damage Do not lift the bath with airjets by the air channels or blower motors or use the air channels or blower motor for structural support of the bath CAUTION R...

Page 9: ...ion Insert the drain tailpiece into the trap Make sure the bath is level and resting on all support blocks Remove the protective tape from the rim Apply a continuous bead of high quality silicone seal...

Page 10: ...d with a cord and plug A licensed electrician must install a dedicated GFCI protected 220V 10A grounded outlet Locate the outlet behind the bath and within 610mm of the blower motor Plug the blower mo...

Page 11: ...im is fully supported Build the bath support frame as shown When the bath is securely positioned before the unit is fully built in install tapware connect plumbing to Run water into the bath and check...

Page 12: ...Do not use powdered cleaners unless the cleaner is fully dissolved in water Solid substances could block the airjets Do not use bleach or ammonia cleaning solutions Chemically active cleaning solution...

Page 13: ...move air switch tube and drain C Air switch is faulty or disconnected C Check air tube connections D Blower motor does not work D Replace blower motor 2 Blower motor starts but there are few or no bub...

Page 14: ...information please visit our website Australia www au kohler com New Zealand www kohler co nz CONTACT AND WARRANTY INFORMATION 1034122 FJ Check Valve Air switch and blower 1128A CP 1122542 80mm Level...

Page 15: ......

Reviews: