![Kohler Mira Decor Installation And User Manual Download Page 32](http://html.mh-extra.com/html/kohler/mira-decor/mira-decor_installation-and-user-manual_1987055032.webp)
32
1365393-W2-A
Note: What to do if something goes wrong. If your product does not work
correctly check that it is installed and commissioned in accordance with
our instructions. If this does not resolve the issue, contact us for help and
advice. Refer to Customer Support page for more details.
Symptom
Possible Cause
Possible Remedy
Low or no flow
Showerhead blocked.
Remove and descale Showerhead.
Hose kinked or blocked.
Check hose and replace if necessary.
Other outlets (e.g. Toilet, garden
hose, washing machine, etc.)
drawing water while the shower is
being used
Turn off other appliances whilst shower
is in use.
The incoming water supply stop
valves, or the appliance isolating
valve, is closed.
Open the stop/isolating valve
completely.
The power is off at the double pole
switch.
Switch on the power at the double pole
switch.
The fuse is blown or the MCB/
RCD has been tripped, indicating
a possible electrical fault.
Renew the fuse or reset the MCB/RCD.
If the fault persists, contact the shower
installer.
Operation of
Temperature Control
has little or no effect on
water temperature
Showerhead blocked.
Remove and descale Showerhead.
Hose kinked or blocked.
Check hose and replace if necessary.
No hot water from
shower, with the knobs
in any position.
Other water outlets are being used
during showering, causing the
water pressure to drop below the
minimum required.
Make sure the other water outlets, such
as the washing machine or dishwasher,
are not in use during showering.
The water pressure is below the
minimum required.
Make sure that the incoming water
supply stop and the isolating valve are
completely open. If the fault persists,
contact the shower installer.
Showerhead continues
to drip after shower
turned off.
It is natural for all shower outlets
to continue to expel water for a
short period of time after use.
It is not uncommon for larger
deluge shower heads to expel
water several hours after use due
to the changes in the ambient
temperature. Ensure all water
outlets are kept enclosed within
the water catchment area.
No Fault with shower
Summary of Contents for Mira Decor
Page 39: ...39 1365393 W2 A Notes ...