26
1493936-W2-A
Servicing
Warning! There are no user serviceable parts inside the shower. Servicing
of the shower must only be carried out by qualified, competent personnel
following the instructions provided in this guide and those provided with
any spare part. Before replacing any parts, ensure that the underlying cause
of the malfunction has been resolved.
Inlet Connector
Assembly
Inlet Filter
Screws
Service
Tunnel
Screw
Cover
Cleaning the Inlet Filter
Warning!
Isolate the electrical and water
supplies before removing the cover.
1
3
4
2
5
6
7
Remove the shower hose.
Note:
Retain the Hose Washer
for further use
Remove the three cover retaining
screws and remove the cover.
Unplug
the multi-connector and
place the cover to one side.
Remove the service tunnel.
Use a suitable spanner to remove
the filter from the inlet connector
assembly. Hold a wrench across
the flats of the inlet connector
assembly to prevent damage to
the connector, whilst removing
the filter.
Remove the filter and rinse under
a running tap to remove any
lodged particles. If necessary, use
a kettle descalent in accordance
w i t h t h e m a n u f a c t u r e r ’s
instructions.
Refit the components in reverse
order.
Note:
The multi-connector
will only locate correctly into the
cover socket in one direction.
Hose
Washer
Multi-