1082081-X2-A
8
Kohler Co.
TROUBLESHOOTING
Symptoms
Probable Causes
Corrective Actions
No flushing
(Indicator not
flashing).
1. No power or mistake connected.
2. There is a mirror or some other reflectible
objects within the sensing distance.
3. The sensing window needs cleaning.
1. Check the power connect.
2. Remove the object.
3. Clean the window.
No flushing or
poor flushing while
the indicator can
flash.
1. Still in the waiting status.
2. Adjusting bolt not fully open.
3. Low water pressure.
4. Filter is obstructed.
5. The connector is not connected well.
1. Wait for 10 minutes.
2. Open the adjusting bolt.
3. Improve water supply.
4. Clean the filter.
5. Check the connector.
Keep flushing
indicator not
flashing.
1. The small hole of diaphragms assembly is
blocked.
2. Foreign objects exist in valve chamber.
1. Clean the small hole of diaphragms
assembly.
2. Clean the valve chamber and diaphragms
with a brush.
Battery indicating
light keeps flashing
and no flushing.
1. Just power cut (AC).
1. Check the power supply.
MAINTENANCE
Urinal Repair :
When repairing, you don’t have to dismount the sensor. Cover the sensing window with tape and work with ease.
CAUTION :
Don’t use very adhesive tape in case the scar will be hard to remove.
Care & Cleaning
Keep the sensor window clean. wipe the soft cloth and mild cleaner.
CAUTION :
a. Do not use dust-removing powder, abrasive powder or cleaner containing oil, acid or alkaline ingredient.
b. Do not spray air-refresher, disinfect, or other deodorizing, cleaning solvent directly into the sensor.
c. Keep wire away from water.
d. Don’t attack the sensor window.
Clean the Filter Screen
If the flushing volume reclines sharply after installation or used for a long time with no cause from water pressure,
the filter may need a wash.
Turn off the fixed cap with filter-key, take out the filter, clean with a brush and reinstall it.
Notice:
Turn off the water supply or tighten the adjusting bolt before cleaning.
1045442
Filter
1045440
Fixed Cap
1021430
Filter-Key