1082081-X2-A
6
Kohler Co.
8.
Make signal wire going through fixing bracket assy. into valve box via bushing. Install fixing bracket assy. into
the gap of panel assy. Adjust fixing bracket assy. vertically with sensing window, press down the panel, move
the active panel of fixing bracket with sensor panel key counterclockwise to fix sensor panel assy.
NOTE :
a. Excessive force should not be posed to avoid tearing to break.
b. Put on clean gloves when installing sensor panel assy. to avoid surface damage caused by cement and sand.
c. When sensing windows of panel is not vertical with the horizontal plane, take out panel assy., loosen screw
of fixing bracket, rotate fixing bracket assy. properly to make it vertical with sensing window, and then tighten
the screws.
9.
Install AC power unit
a. Put AC power unit into cassette as shown in the right figure.
b. Connect DC wiring terminal with solenoid terminal separately.
c. Connect AC wiring terminal in the AC power unit with another one in AC bushing, and wrap with insulated tape
CAUTION :
a. Do not connect 220V AC power supply to DC wiring terminal.
b. Do not damage the covering of AC power unit or remove screws to avoid leakage.
NOTE:
a. Keep the connector away from water.
b. Don’t mistake the direction of inlet and outlet.
c. Do not connect the DC output of AC power unit to AC power supply.
d. Do not connect to power supply during installing process. Connection line is not supplied. It is
recommended to use AC connection wire with insulating sleeve. It is recommended to use AC power cord
with the nominal section area no less than 0.5mm
2
. For DC connection line, it is better to use wire with the
nominal section area no less than 0.3mm
2
. The cord should be cut according to actual installation
requirements (better less than 10m).
e. The mains must be protected with appropriate fuse.
f. Please confirm the power supply and water supply have been shut off before maintaining the products with
AC power related.
Connect
to sensor
Connect AC
Power Supply
Connect
to sensor
Connect AC
Power Supply
Sensing Window
Bushing
16306X-NA
AC Power Unit
DC Wiring
Terminal
DC Wiring Terminal
AC Wiring Bushing
Solenoid Valve
Terminal
Sensor Panel
Assy
Signal Wire
Fixing Bracket
Assy
Sensor Panel Key