4. Install the Finished Wall
Install the water-resistant wall board.
Cut out a 4-1/8
″
(105 mm) round hole, centered on the pipe
nipple at each desired installation location.
Install the finished wall material.
5. Install the Pipe Nipple
Remove the nipple.
NOTE:
The minimum distance between the face of the tee/elbow
and the surface of the finished wall should be 2-1/4
″
(57 mm). The
measurement for typical installations is 2-7/8
″
(73 mm).
Measure the distance from the face of the tee/elbow to the
surface of the finished wall. Make any adjustments as needed.
If your measurement is between 2-1/4
″
(57 mm) and 2-3/4
″
(70
mm):
Use a close pipe nipple.
If your measurement is between 2-3/4
″
(70 mm) and 3-1/4
″
(83
mm):
Use a 1-1/2
″
pipe nipple.
Thread the nipple into the tee/elbow and hand tighten.
Measure the distance from the end of the nipple to the surface of
the finished wall. Verify that the distance is at least 1-1/2
″
(38
mm) and no more than 2
″
(51 mm).
Remove the nipple.
Finished Wall
Cutout
Tee
(or Elbow)
Cutout
Ø 4-1/8" (105 mm)
2-1/4"
(57 mm)
Min
Ø 4-1/8"
(105 mm)
Nipple