background image

INSTALLAZIONE 

– INSTALLATION  

 

 

 

 

KIT SOFFIONI MySlim A CONTROSOFFITTO 

 

KIT MySlim SHOWER HEADS FOR FALSE CEILING 

 

 

 

 
 
 
 

Art. KIT00006 

 
 
 
 

 

 

 

Summary of Contents for Calflex MySlim

Page 1: ...INSTALLAZIONE INSTALLATION KIT SOFFIONI MySlim A CONTROSOFFITTO KIT MySlim SHOWER HEADS FOR FALSE CEILING Art KIT00006 ...

Page 2: ...a manutenzione non devono essere eseguite dai bambini senza supervisione Negli apparecchi non vi sono componenti contenenti mercurio e amianto WARNINGS The plant must be made by an authorised staff and must be certified at the norms in use in the country where the installation is made All the material used must be conformed to the safety requirements forecast for this type of installation as per t...

Page 3: ...3 ...

Page 4: ... una distanza dall uscita G1 2 M compresa tra i 135 mm e 160 mm Preparare un foro da circa Ø150 mm nel controsoffitto in prossimità del collegamento idraulico Run a pipe to the ceiling with G1 2 M outlet for the showerhead and prepare a false ceiling that must be at a distance between 135 mm and 160 mm Prepare a Ø150 mm hole in the false ceiling near the pipe outlet ...

Page 5: ...ALLATION Avvitare il raccordo filettato utilizzando una chiave da 24 mm serrandolo a tenuta con canapa o similari Then screw hermetically the threaded connection using a 24 mm wrench together with hemp or similar materials ...

Page 6: ...di avvitatura Put the felt covers 1 and the protection gasket 2 supplied on the upper shower head surface Then screw the kit to the shower head using a 24 mm wrench and a 22 mm wrench The gasket 2 does not penetrate dust and or air inside the cavity between the ceiling and the false ceiling as well as makes soundproof the area The felt covers 1 protect the false ceiling from any possible scratches...

Page 7: ... a contatto con il controsoffitto Questa installazione è la soluzione ideale anche per soffioni di grandi dimensioni e per qualsiasi soffione con uno snodo da G 1 2 When the installation is completed make sure that the shower head is perfectly stick to the false ceiling This installation is the ideal solution for shower heads of huge dimensions and for any shower head with G 1 2 swivel ...

Page 8: ...EX S r l si riserva la possibilità di applicare modifiche tecniche sui suoi articoli senza nessun preavviso For a continuous improvement policy CALFLEX S r l reserves the right to modify the technical features of its articles at any time without notice ...