background image

1298232-T01-C

-2-

0.18~0.55MPa.

0.5L

0.18~0.55MPa.

1L

1~ 55 C

1~ 55 C

0.05~0.86MPa.

0.05~0.86MPa.

70cm

(

50~70cm)

70cm

(

50~70cm)

2

5

(

)

2

5

(

)

2

7

(AAA

2)

2

7

(AAA

2)

SPECIFICATIONS

Power

Power

Power

Model

Model

Model

Liter per flushing

Liter per flushing

Liter per flushing

Temperature

Temperature

Temperature

Starting pressure

Starting pressure

Starting pressure

Sensing distance

Sensing distance

Sensing distance

Testing time

Testing time

Testing time

Flushing mode

Flushing mode

Flushing mode

Note: the sensing distance in the table is measured with a 30 X 30cm white board as the reflecting surface.

2

Water pressure at 0.18~0.55 MPa: Average flushing no more than 0.5L

Water pressure at 0.18~0.55 MPa: Average flushing no more than 1L

Water pressure at 0.18~0.55 MPa: Average flushing no more than 2.5L

Environmental temperature: 1 to 55 C

Environmental temperature: 1 to 55 C

Environmental temperature: 1 to 55 C

0.05~0.86MPa

0.05~0.86MPa

0.05~0.86MPa

70cm away from sensing window (Automatic adjustiment range: 50~70cm)

70cm away from sensing window (Automatic adjustiment range: 50~70cm)

70cm away from sensing window (Automatic adjustiment range: 50~70cm)

About 2 seconds or 5 seconds (Automatic adjustiment)

About 2 seconds or 5 seconds (Automatic adjustiment)

About 2 seconds or 5 seconds (Automatic adjustiment)

Flushing after used

Flushing after used

Flushing after used

K-20099T-Y

K-20099T-W

K-20099T

K-20099T-Y

K-20099T-W

K-20099T-YC05

K-20099T-WC05

K-20099T-C05

K-20099T-YC05

K-20099T-WC05

2 AAA size alkaline batteries

"

"

2 AAA size alkaline batteries

"

"

2 AAA size alkaline batteries

"

"

220V AC 50/60Hz

220V AC 50/60Hz

220V AC 50/60Hz

220V AC 50/60Hz

220V AC 50/60Hz

Summary of Contents for K-20099T

Page 1: ... care cleaning and warranty information please leave instructions for the consumer Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2018 The product complies with GB 6952 2015 GB 28377 2019 ASME A112 19 2 2018 GB 6952 2015 GB 28377 2019 Open end adjustable wrenches Tape measure Basin wrench Pipe wrench Square Level Pliers Socket wrench with sockets S...

Page 2: ...Water pressure at 0 18 0 55 MPa Average flushing no more than 2 5L Environmental temperature 1 to 55 C Environmental temperature 1 to 55 C Environmental temperature 1 to 55 C 0 05 0 86MPa 0 05 0 86MPa 0 05 0 86MPa 70cm away from sensing window Automatic adjustiment range 50 70cm 70cm away from sensing window Automatic adjustiment range 50 70cm 70cm away from sensing window Automatic adjustiment ra...

Page 3: ...ecommended dimensions for installation only please adjust according to actual situation inlet I a b A c G 1 2 d 450 183 117 680 148 252 116 160 85 250 600 410 316 Supply 50ext 30 X 30cm2 0 18 0 55MPa 2 5L 1 55 C 0 05 0 86MPa 70cm 50 70cm 2 5 2 7 AAA 2 K 20099T K 20099T C05 220V AC 50 60Hz Notice To ensure an effective flush performance strongly recommended inner diameter of water supply including ...

Page 4: ... waste pipe connector shall be soaked into water for 2 seconds to lubricate B C Wall 50 Pre installed waste pipe connector Insert the connector into the waste pipe in the wall along this direction Move the gasket to front of the pipe before connecting to the urinal C Install urinal 1 Hang the urinal onto the hangers 2 3 4 Apply silicone sealant between urinal and wall Align the waste pipe connecto...

Page 5: ...Adjust Upwards and Downwards E Install the drain and the plastic trap NOTE E 1 Put the washer onto the drain and insert it into the hole 2 Put the gasket and nut on the bottom Do not over screw the nut in this step because it is to be screwed tight in the next step after the pipe is installed 1 2 pre installed in factory 3 Connect the hose with the trap 4 As shown in the picture screw the crossbar...

Page 6: ...b 220V DC c 1 K 20099T YC05 K 20099T WC05 K 20099T C05 3 When installing the power unit on the ceiling please chisel out a slot and layout bushing according to Fig and thread wire through the bushing One AC power unit can supply two sensors at most CAUTION 3 2 2 AC power unit connected to electric control box by connection wire The length of the connection wire should keep the connector out of the...

Page 7: ... than 0 5mm is also recommended DC connection line use wire of which the nominal section area is not less than 0 3mm It is cut according to acted installation requirements The length of cut wire is recommended less than 10m d The head AC power supply must be protected with appropriate fuse e Please confirm the AC power supply and water supply should be shut off before maintaining the products with...

Page 8: ...he sensor has been adjusted to after use flushing If the action is not completed during this 10 minute or you need to restore the working status to dualflush plug off the power cord and reconnect the power supply until the indicator stops flashing and repeat the above procedures 2 The diction time is set as 2s to avoid improper function in narrow toilets the detection time is automatically set fro...

Page 9: ... 30 Notice Used in places of low water pressure If the flushing amount is limited due to low water pressure you can set a long time washing with flushing control stick Operate as follows Ten minutes after power on you can switch between two wash times by putting the flushing control stick near the right side of sensing window There will be a 2 second rinse after you complete the setting If you nee...

Page 10: ...ose of valve assy and then take out the filter Clean it with a brush and reinstall a Turn off the water supply before cleaning the filter also power off when used the AC power supply b Avoid damaging or losing the filter during cleaning Caution a b MAINTENANCE Filter Bracket of Valve Connector Inlet Hose of Valve Assy 10 Care Clean Keep the sensing window clean Wipe with soft cloth and mild cleane...

Page 11: ...e small hole of valve core with thin steel wire 2 Wash the filter of valve core with a brush Replace batteries Please make following checks before repair Symptoms Probable causes Corrective actions If the trouble remains after above mentioned actions are taken please contact with us via distributor 1 2 3 1 2 3 1 2 K 20099T Y K20099T W K 20099T 1 2 No flushing or poor flushing while the indicator c...

Page 12: ... to 220V AC power supply corresponding protective measures should be taken 9 Please confirm no water penetration at the connection area of AC wire and the connection area is not easy to be affected by damp 10 Don t connect power unit to AC power supply until the sensor installation is finished 11 The head AC power supply must be protected with appropriate fuse 12 Please confirm the AC power supply...

Reviews: