B. Methods two and three: During remote installation, fix

the cover onto the tank and pull the air hose to the
panel. Reserve access panel at front or top to ensure
removal and installation of cover.

Method two: During remote plate installation,
7~20mm thickness is recommended for the wall of
the pinch plate and at least 80

3mm gap is reserved.

Method three: During remote installation of mask, 4
holes with diameter of 10mm and depth of 12mm are
needed to be reserved at the locating hose. Drill
10mm holes through air hose on the side of the mask.

Recommended installation hole size of

X

mm to remote plate installation.

297

157

B.

7~20mm

80

3mm

4

10mm

12mm

10mm

X

mm

297

157

Air hose

Pinch plate

Finished wall

Supporting
Board

7~20mm recommended

7~20mm

297

157

+2

0

+2

0

+2

0

+2

0

+2

0

+2

0

Pinch plate installation

Screw

Air hose

Pinch plate

Pinch plate

Finished wall

Faceplate

Supporting Board

C. Method four: Cut apart the cable of the air hose. Pull

it out from the front of the tank and meanwhile
reserve the access panel. Fix the four plates with
screws and then fix the support board.

No direct contact between the faceplate and the
tank.
7~20mm thickness recommended for the wall of
the pinch plate.

Note:

Recommended installation hole size of

X

mm to remote plate installation.

297

157

C.

7~20mm

X

mm

297

157

Method four:

Press from front

Air hose

Pinch plate

Finished wall

7~20mm recommended

7~20mm

+2

0

+2

0

+2

0

+2

0

80

3mm gap reserved

80

3mm

80

3mm gap reserved

80

3mm

Suggested/

80

3

Air hose

Finished
wall

Fix Mask Onto Wall

78

10 Hole through hose
10

10 Depth 12,
Space reserved
10

12

Cover,Top

Cover,Front

1402749-T01-A

Summary of Contents for Escale K-23076T-BNS

Page 1: ...91T S K 23076T CPS K 23076T BNS K 23077T CPS K 23077T BNS K 25449T NS Water Efficiency Grade 2 for K 24932T GS Please read these instructions carefully to familiarize yourself with the required tools...

Page 2: ...GS Includes BEAM Manual Toilet Squat Flush Valve K 77681K G Includes ESCALE Quick Release QC Seat K 4417T 2P ESCALE WF Toilet BEAM SR D CP K 23076T CPS Includes Bowl K 23078T DPS Includes BEAM Toilet...

Page 3: ...hed Wall Finished Wall Install Flushing Mechanism 1 Install The Tank 1 Turn the water supply off before installing the new toilet 2 Install the concealed tank system in wall before decorating the wall...

Page 4: ...ll Caution 2 1 1 2 Fig 3 3 UNIT mm Water Supply 345 O utlet 110 130 180 S trap 345 Outlet 185 Water Supply P trap 4 3 3 15 38 3 Remove the bowl and place the installation template on the floor Drill t...

Page 5: ...nto the reserved drainage pipe Fig 7 Push the bowl to insert the drainage hole into the S trap and also insert the water pipe into the outlet of the in wall tank 4 PVC 7 UNIT mm Fig 6 6 Fig 7 7 185 18...

Page 6: ...use of using cement Do not throw into the toilet what is easy to block it such as newspaper paper pilch sanitary towel Do not bump the vitreous china with great force to prevent it from damaging and l...

Page 7: ...pares not provided by Kohler This product complies with GB26730 2011 GB26730 2011 Ordering Information HT201 PNE IWT W F 2 6 4 0 K 25439T PNE NA HT201 PNE IWT W F 3 0 4 5 K 25440T PNE NA HT201 PNE IWT...

Page 8: ...4151T Design And Installation Concept Of In wall Tank Installation of in wall tank is much easier and nice looking comparative to that of traditional tank Meanwhile the space layout will be more reaso...

Page 9: ...erature 1 45 C C C C C C C C 1 55 1 45 Full flushing volume Half flushing volume 6 L 3 L 6 L 3 L 0 0 0 0 K 25440T PNE NA K 25440T PM NA K 25440T RU NA K 25440T ML NA K 25443T PNE NA K 25443T PM NA K 2...

Page 10: ...PM K 25440T RU K 25440T ML K 25441T PNE Installed with K 20341T PNE K 20341T PNE Method one Press from top Method two Remote plate installation Method three Remote installation of mask Method four Pr...

Page 11: ...ggested faceplate installation area R1000mm 59 1 Finished wall Finished Floor Height to floor is decided by bowl K 23055T PNE 155 5 1 51 1 K 24149T K 24151T 225 1 160 1 20 72 Suggested 80 3 Kohler res...

Page 12: ...ove paper board support block and plug above bracket assembly 1 2 Insert the frame screw and screw cap in the holes of fixing frame lock the frame screw with nut then tighten the frame screws on the f...

Page 13: ...the tank to remain level 4 A B Hexagonal Screw Loosen Tighten Level Medinm Allen Key Adjustable Bracket Spanner Screw Screw Screw Expanding Bolt Cap Expanding Bolt Cap Washer Washer B Floor Discharge...

Page 14: ...75890T PNE K 24149T K 24151T Access Panel Installation Methods There are four ways to install access panel Method one Press from top Method two Remote plate installation fix four plates with screws Me...

Page 15: ...mmended for the wall of the pinch plate and 80 3mm gap is reserved Method three During remote installation of mask 4 holes with diameter of 10mm and depth of 12mm are needed to be reserved at the loca...

Page 16: ...plate Pinch plate Finished wall Finished wall Faceplate Supporting Board Supporting Board Method four Press from front 7 20mm recommended 7 20mm 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 0 2 K 23055T PNE access...

Page 17: ...rve access panel at front or top of the tank Note D Installation of Toilet D 1 Install the inlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pen...

Page 18: ...needed it should be adjusted with screwdriver or by hand Then apply lubricant to drainage pipe and limber pipe to ensure a smooth installation 4 48mm 58mm 48mm 58mm Long Screw Lubricant 5 Install the...

Page 19: ...NE K 24149T K 24151T 2 Tighten four screws to LOCK mark after installing supporting board as shown 2 LOCK 3 Install the big flush air hose and small flush air hose to the cover Cut the excessive parts...

Page 20: ...ceplate fixed frame installation direction 3 2 1 3 2 1 Half Flush Button Air Hose Faceplate Full Flush Button 2 2 Connect air hose to faceplate from water tank 3 3 Insert faceplate into faceplate fixe...

Page 21: ...d then locate the installation hole of fixing bracket Mark on the wall for appropriate position for fixing bracket and drill four holes with diameter of 12mm and depth of 80mm with churn drilling as s...

Page 22: ...ethod three Remote installation of mask Method four Press from front fix four plates with screws 1 K 20341T PNE K 75890T PNE K 24149T K 24151T Method one Press from top Method four Press from front Me...

Page 23: ...Supporting Board 7 20mm recommended 7 20mm 297 157 2 0 2 0 2 0 2 0 2 0 2 0 Pinch plate installation Screw Air hose Pinch plate Pinch plate Finished wall Faceplate Supporting Board C Method four Cut ap...

Page 24: ...the air hose to the panel Reserve access panel at front to ensure removal and installation of cover Recommended installation hole size of 146 X 41 mm 146 X 41 mm 41 146 2 0 2 0 Pinch Plate Wall Thick...

Page 25: ...OF THE OUTLET VALVE Faceplate Faceplate Connect to air hose 3 Dismantle supporting board as shown 3 2 Pay special attention when dismantle supporting board 4 lock nuts all bolts shall align with OPEN...

Page 26: ...h aside the pivot snaps of the big flush and small flush towards lower left to fix back the bracket Lock the snap Note 7 Lever Snap Snap Locked Fastener Fastener 8 Hold fastener by hand as shown pull...

Page 27: ...irst then loosen and take out the tighten nut and wash the waste on filtration net with clean water Then reset the tighten nut to the original position A Tighten Close Open Corner Open A Tighten Close...

Page 28: ...adjust the water level The floating box of the inlet valve is blocked by wastes so the water is leaked from the overflow pipe A No water supply B The water supply stop is closed Readjust the position...

Reviews: