故障现象
判断分析
解决方法
皂液器底座的
红色LED灯每
六秒闪烁一次
皂液余量较低(起
动后用完了一个
循环的70%)
用皂液重新装满皂液
盒,并起动皂液器
皂液器底座的
红色LED灯每
六秒闪烁两次
皂液用尽或极少
(起动后用完了一
个循环的90%)
用皂液重新装满皂液
盒,并起动皂液器
皂液器底座的
蓝色LED灯每
六秒闪烁一次
电池电量不足
(低于4.8V)
更换电池并起动皂
液器
皂液器底座的
蓝色LED灯每
六秒闪烁两次
电池没电
(低于4.5V)
更换电池并起动皂
液器
不出皂液
感应窗脏了
用干净、干燥的软
布擦拭感应窗
出液量很小或
没有
喷嘴堵塞
拆下喷嘴和发泡
组件, 用温水清洗
止回阀堵塞
从皂液管上卸下止回
阀,用温水清洗
导管(皂液和
空气)已断开
将导管重新连接
至控制盒
感应器电缆已
断开
重新连接感应器电缆
没有电源或连接
错误
检查电源连接
重新装满后未启
动皂液泵
启动泵
皂液管/止回阀
堵塞
用温水清洁皂液管/
止回阀
只有气泡排出
皂液泵出口堵塞 拆下皂液泵管,用温
水清洗皂液泵的出口
皂液泵泄漏
订购并安装新的皂
液泵
气泵已断开
检查气泵连接,将导
管重新连接至控制盒
气泵/导管堵塞
拆下气泵管,用温水
清洗气泵的出口
气泵不工作
订购并安装新的气泵
皂液泵无法正常
工作
订购并安装新的皂
液泵
没有泡沫排
出,只有洗手
液排出
皂液泵出口堵塞 拆下皂液泵管,用温
水清洗皂液泵的出口
感应距离内存在
物体
将物体移出感应
距离,等待20秒,
然后再启动皂液器
Symptoms
Probable Cause Recommended Action
A red LED light
flashes at the
base of the soap
dispenser once
every 6 seconds
The soap is
running low (70%
of cycle used
after priming)
Refill the soap reservoir
and prime the soap
dispenserwith soap
A red LED light
flashes at the
base of the soap
dispenser twice
every 6 seconds
The soap is out
or very low (90%
ofcycle used
after priming)
Refill the soap reservoir
with soap and prime the
soap dispenser
A blue LED light
flashes at the
base of the soap
dispenser once
every 6 seconds
The battery is
running low
(lower than 4.8
volts)
Replace the batteries and
prime the soap dispenser
A blue LED light
flashes at the
base of the soap
dispenser twice
every 6 seconds
The battery is
out of power
(lower than 4.5
volts)
Replace the batteries and
prime the soap dispenser
No soap
dispenses
The volume of
soap dispensed
is small or
nonexistant
The sensor lens
is dirty
Wipe the sensor lens with
a clean, dry, soft cloth
The sensor cable
is disconnected
Reconnect the sensor
cable
The tube (soap
and air) is
disconnected
Reconnect the tube to the
control box
No power supply
or wrong
connection
Check the power supply
connection
The soap pump
is not primed
after refilling
Prime the pump
The dispensing
tube/check valve
is blocked
Clean the dispensing
tube/check valve
with warm water
The dispensing
tube/check valve
is blocked
Clean the dispensing
tube/check valve
with warm water
The nozzle is
clogged
Remove the soap nozzle
and foaming assembly.
Clean with warm water
Only air bubbles
are dispensing
The soap pump
outlet is clogged
Remove the soap pump
tubing
No foam is
dispensing. Only
liquid soap is
dispensing
The air pump is
disconnected
Check the air pump
connection and reconnect
the tube to the control box
The air pump/
tube is clogged
Remove the air pump
tubing. Clean the air
pump outlet with
warm water
The air pump is
not working
Order and install a new
air pump
The soap pump
is leaking
Order and install a new
soap pump
The check valve
is clogged
Remove the check valve
from dispensing tube.
Clean with warm water
The soap pump
is not working
correctly
Order and install a new
soap pump
15