11.21
Section 11
Reassembly
11
Figure 11-72. Connecting Governor Spring to
Governor Lever.
Install Throttle and Choke Controls
1. Connect the choke linkage to the carburetor and
choke actuator lever.
2. Install the standard throttle control bracket and the
air cleaner support bracket (if used) to the cylinder
heads using the four hex. flange screws. Torque
the screws to
10.7 N·m (95 in. lb.)
into new holes,
or
7.3 N·m (65 in. lb.)
into used holes.
Figure 11-73. Standard Control Bracket.
Figure 11-74. Throttle/Choke Control Bracket Detail.
Item
Description
1
Bracket, speed control
2
Clamp, cable (some applications)
3
Kill Switch (some applications)
4
Lever, choke (top position)
5
Lever, throttle control (middle)
6
Linkage, choke control
7
Lever, throttle actuator (bottom)
8
Screw, M5x0.8x20
9
Washer, wave
10
Washer, flat (3)
11
Spring, choke return
12
Nut, M5x0.8 lock
Kohler Engine Parts Call K&T 606-678-9623 or 606-561-4983