Measure the distance of the glass between
the wall jamb and the tray ‘A’. Cut the
splashguard to size cutting at the wall jamb end.
Fit the splashguard to the bottom of the glass
10
19
CFI230J
STEP
19
STEP
20
If the any further adjustment is required to make
the glass panel vertical turn the 4 screws ‘D’
until the panel is in the correct position
D
STEP
18
STEP
21
A
CFI230J
A
B
C
The edge of the glass should fit against the end
of the slot in the tray ‘B’. To adjust the glass
loosen the 4 screws ‘C’ and move the panel until
it is the correct postion. Re-tighten screws
Check the wall channel and jamb is vertical.
Loosen screws ‘A’ to adjust from side to side.
Re-tighten screws
Check end of
glass is vertical
STEP
23
Check top rail is level. Draw around parking block
STEP
22
Note:
The lintel is supplied as a RH unit.
For LH versions loosen the panel clamps
and turn them through 180
o
Ensure glass panels
are parallel to each other
Loosely fit the parking block into the wall mount ‘A’. Lift the lintel onto the glass. The panel clamps
fit over the top edge of the glass and should be equally spaced on each panel
A
m
m
0
±
Summary of Contents for CFI230J
Page 2: ......