Kohler 4EFRKM Operation Download Page 8

TP-6081 4/00

IV

Safety Precautions and Instructions

Hot Parts

Hot engine and exhaust system.
Can cause severe injury or death.

Do not work on the generator set until
it cools.

WARNING

Servicing the exhaust system. Hot
parts can cause severe injury or
death.

Do not touch hot engine parts.

The

engine

and

exhaust

system

components become extremely hot
during operation.

Combustible materials.

Fire can

cause severe injury or death.

A hot

exhaust system can ignite adjacent
combustible materials. Do not locate
electrical

wiring,

fuel

lines,

or

combustible

materials

above

the

exhaust muffler.

Exercise caution

when parking your vehicle to prevent
the exhaust system and hot exhaust
gases from starting grass fires.

Combustible materials.

Fire can

cause severe injury or death.

A hot

generator set can ignite debris in the
compartment. Keep the compartment
and generator set clean and free of
debris and combustible materials to
minimize the possibility of fire. Do not
block the fuel/oil drain opening in the
generator set mounting tray.

Cut a

corresponding hole in the subfloor, if
used, for the drain opening.

Moving Parts

Hazardous voltage.
Can cause severe injury or death.

Operate the generator set only when
all guards and electrical enclosures
are in place.

Moving rotor.

WARNING

Rotating parts.
Can cause severe injury or death.

Operate the generator set only when
all guards, screens, and covers are in
place.

WARNING

Tightening the hardware.

Flying

projectiles can cause severe injury
or death.

Loose hardware can cause

the hardware or pulley to release from
the generator set engine and can cause
personal

injury.

Retorque

all

crankshaft and rotor hardware after
servicing. Do not loosen the crankshaft
hardware or rotor thrubolt when making
adjustments or servicing the generator
set. Rotate the crankshaft manually in
a clockwise direction only. Turning the
crankshaft

bolt

or

rotor

thrubolt

counterclockwise

can

loosen

the

hardware.

Servicing the generator set when it
is operating. Exposed moving parts
can cause severe injury or death.

Keep hands, feet, hair, clothing, and
test leads away from the belts and
pulleys when the generator set is
running. Replace guards, screens, and
covers before operating the generator
set.

Notice

NOTICE

This

generator

set

has

been

rewired from its nameplate voltage
to

246242

NOTICE

Voltage reconnection.

Affix a notice

to the generator set after reconnecting
the set to a voltage different from the
voltage on the nameplate.

Order

voltage reconnection decal 246242
from

an

authorized

service

distributor/dealer.

NOTICE

Hardware damage.

The engine and

generator set may use both American
Standard and metric hardware. Use
the correct size tools to prevent
rounding of the bolt heads and nuts.

NOTICE

When replacing hardware, do not
substitute

with

inferior

grade

hardware.

Screws and nuts are

available in different hardness ratings.
To

indicate

hardness,

American

Standard hardware uses a series of
markings, and metric hardware uses a
numeric system. Check the markings
on the bolt heads and nuts for
identification.

NOTICE

Canadian installations only

.

For

standby service connect the output of
the generator set to a suitably rated
transfer switch in accordance with
Canadian Electrical Code, Part 1.

NOTICE

This generator set does not comply
with United States Coast Guard
(USCG) requirements and must not
be used for marine applications.

For

marine installations use only generator
sets specified for marine use. USCG
Regulation 33CFR183 requires that a
generator

set

must

be

ignition

protected

when

used

in

a

gasoline-fueled environment.

Summary of Contents for 4EFRKM

Page 1: ...Commercial Mobile Generator Sets Models 5ERKM 4EFRKM TP 6081 4 00 Operation...

Page 2: ...Engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING California Proposition 65...

Page 3: ...et 4 2 4 3 Stopping the Generator Set 4 Section 3 Scheduled Maintenance 5 3 1 General Maintenance 5 3 2 Service Schedule 6 3 3 Lubrication System 8 3 3 1 Oil Specifications 8 3 3 2 Oil Check 8 3 3 3 O...

Page 4: ...TP 6081 4 00 Table of Contents Notes...

Page 5: ...t the power to the battery charger if equipped 2 Remove the battery cables negative lead first Reconnect the negative lead last when reconnecting the battery Follow these precautions to prevent the st...

Page 6: ...to the following D Light headedness dizziness D Physical fatigue weakness in joints and muscles D Sleepiness mental fatigue inability to concentrate or speak clearly blurred vision D Stomachache vomi...

Page 7: ...whenever electricity is present Open the main circuit breakers of all power sources before servicing the equipment Configurethe installation to electrically ground the generator set transfer switch a...

Page 8: ...thecrankshaft hardwareorrotorthrubolt whenmaking adjustments or servicing the generator set Rotate the crankshaft manually in a clockwise direction only Turning the crankshaft bolt or rotor thrubolt c...

Page 9: ...Assistance Service Information Please contact a local authorized distributor dealer for sales service or other information about Kohler Generator Division products To locate a local authorized distri...

Page 10: ...readily available for future reference Record field installed kit numbers after installing the kits Generator Set Identification Numbers Record the product identification numbers from the generator s...

Page 11: ...23316 Spark Plug 63 132 01 S Spray Paint Black 221292 Voltage Regulator Fuse 10 amp 223316 Figure 1 Maintenance and Service Parts x in 001 004 List of Related Literature Figure 2 identifies related li...

Page 12: ...TP 6081 4 00 iv Maintenance and Service Parts Related Literature Notes...

Page 13: ...ide 11 Lifting eye 12 Muffler 13 Exhaust outlet nonservice side 14 Spark plug 15 Air cleaner 16 Carburetor 17 Oil drain valve 18 Oil check oil fill 19 Fuel feed pump 20 Fuel inlet 21 Cooling air inlet...

Page 14: ...TP 6081 4 00 2 Section 1 Service Views Notes...

Page 15: ...vel Check the fuel level and keep the tank s full to ensure adequate fuel supply Oil Level Maintain the oil level at or near not over the full mark on the dipstick Operating Area Check for obstruction...

Page 16: ...arging Fuse This fuse protects the battery charging circuitry Voltage Regulator Fuse This fuse protects the voltage regulator circuitry Remote Start Connector A 6 pin connector on the controller s bac...

Page 17: ...use bothAmericanStandardandmetrichardware Usethecorrect size tools to prevent rounding of the bolt heads and nuts See the Safety Precautions and Instructions at the beginning of this manual before att...

Page 18: ...nkcase 3 3 4 X 20 hrs break in period X COOLING SYSTEM Check the air intake and cooling areas for obstructions and clean as necessary X Check X Clean IGNITION SYSTEM Check the spark plug condition adj...

Page 19: ...nd have it serviced if necessary X ENGINE AND MOUNTING Check for fuel and oil leakage X Retighten all nuts and bolts X Check the mounting bolts vibromounts and tighten as necessary X 200 hrs Check and...

Page 20: ...ove it Maintain the oil level between the Full and Add marks on the dipstick as shown in Figure 3 2 See Section 1 Service Views for the dipstick location 1 TP 5586 3 2 1 Full mark 2 Add mark Figure 3...

Page 21: ...t Dispose of used engine oil and other contaminants in a safe approved manner 3 4 Fuel System 3 4 1 Fuel Specifications Use a clean good quality unleaded fuel with an octane number of 87 Use fresh gas...

Page 22: ...s occupants install a carbon monoxide detector Consult the coach builder or dealer for approved detector location and installation Inspect the detector before each generator set use In addition to rou...

Page 23: ...Gap bridged spark plug Built up deposits and gap between the electrodes closing Oil or carbon fouling Clean and regap the spark plug Oil fouled spark plug Wet black deposits on the insulator shell bor...

Page 24: ...mm 0 028 0 031 in 7 Use a gapping tool to gently bend the side electrode closer to or farther from the center electrode to set the correct gap See Figure 3 6 Position the side electrode directly over...

Page 25: ...cid Battery gases Explosion can cause severe injury or death Battery gases can cause an explosion Do not smoke or permit flames or sparks to occur near a battery at any time particularly when it is ch...

Page 26: ...d moisture from mixing with the fuel 5 Remove the spark plug Pour approximately 1 tablespoon of engine oil into the spark plug hole Crank the engine two or three revolutions to lubricate the cylinder...

Page 27: ...he generator set installation manual I M and the engine service manual Engine S M to correct the indicated problem Corrective action and testing often require knowledge of electrical and electronic ci...

Page 28: ...TP 6081 4 00 16 Section 4 Troubleshooting Notes...

Page 29: ...ot locked tight x x x Disconnect the engine harness twist lock connector then reconnect it to the controller ctrica Loose or inoperative spark plug wire x x x x x 3 8 Reconnect or replace wire Elec Fa...

Page 30: ...TP 6081 4 00 18 Section 4 Troubleshooting Notes...

Page 31: ...gative lead last when reconnecting the battery Follow these precautions to prevent the starting of the generator set by the remote start stop switch Hazardous voltage Can cause severe injury or death...

Page 32: ...TP 6081 4 00 20 Section 5 Diagrams and Drawings GM11960 Figure 5 1 Schematic Wiring Diagram...

Page 33: ...TP 6081 4 00 21 Section 5 Diagrams and Drawings GM11960 Figure 5 2 Point to Point Wiring Diagram...

Page 34: ...TP 6081 4 00 22 Section 5 Diagrams and Drawings Notes...

Page 35: ...e CWC city water cooled cyl cylinder D A digital to analog DAC digital to analog converter dB decibel dBA decibel A weighted DC direct current DCR direct current resistance deg degree dept department...

Page 36: ...onal Safety and Health Administration O V overvoltage oz ounce p pp page pages PA packed accessory PC personal computer PCB printed circuit board pF picofarad PF power factor ph phase PHC Phillips hea...

Page 37: ...Log Use the log below to keep a cumulative record of operating hours on your generator set and the dates required services were performed Enter hours to the nearest quarter hour OPERATING HOURS SERVIC...

Page 38: ...TP 6081 4 00 A 4 Appendix Notes...

Page 39: ......

Page 40: ...381 Web site www kohlergenerators com Fax 920 459 1646 U S A Sales Fax 920 459 1614 International For the nearest sales and service outlet in U S A and Canada Phone 1 800 544 2444 Kohlerr Power System...

Reviews: