TP-6137 5/03
17
Section 4 Intake and Exhaust System
Section 4 Intake and Exhaust System
4.1 Air Intake Silencer/Filter
At the interval specified in the service schedule, clean
the air intake screen. Clean the silencer more frequently
if the generator set operates in dirty, dusty conditions.
TP-6134
1. Air Cleaner
1
Figure 4-1
Air Cleaner
TP-6134
1. Air cleaner screen
1
Figure 4-2
Air Cleaner Screen
Air Cleaner Service/Replacement
A dry-type air cleaner silences and filters the intake air.
The air intake silencer assembly connects to the intake
manifold via a flexible hose.
1. Remove the four screws to remove the air cleaner
cover.
2. Remove the air cleaner screen.
3. Tap the screen lightly against a flat surface to
dislodge loose surface dirt. Do not clean in any
liquid or use compressed air as these will damage
the screen.
4. Examine the screen and housing for damage and
wear. Replace the screen or housing if necessary.
5. Wipe the air cleaner cover and base with a clean
rag to remove any dirt. Ensure that dirt does not
enter the intake port.
6. Make sure that the sealing surfaces fit correctly,
and replace the four screws.
Summary of Contents for 3.5EFOZ
Page 1: ...Marine Generator Sets Includes Engine Maintenance Models 4EOZ 3 5EFOZ TP 6137 5 03 Service ...
Page 10: ...TP 6137 5 03 VI Safety Precautions and Instructions Notes ...
Page 12: ...TP 6137 5 03 ii Service Assistance Notes ...
Page 28: ...TP 6137 5 03 16 Section 3 Scheduled Maintenance Notes ...
Page 42: ...TP 6137 5 03 30 Section 5 Fuel System Notes ...
Page 48: ...TP 6137 5 03 36 Section 6 Cooling System Notes ...
Page 102: ...TP 6137 5 03 90 Section 10 Generator and Engine Disassembly Reassembly Notes ...
Page 104: ...TP 6137 5 03 92 Section 11 Wiring Diagrams 11 1 Wiring Diagram Schematic GM20645 B ...
Page 105: ...TP 6137 5 03 93 Section 11 Wiring Diagrams 11 2 Wiring Diagram Point to Point GM20645 B ...
Page 106: ...TP 6137 5 03 94 Section 11 Wiring Diagrams Notes ...
Page 114: ......
Page 115: ......