27
Solid state type, reed switch type
Symbol
Double acting type
Single acting push type
Single acting pull type
Non-rotating double acting type / double acting type with guide
Sensor switches
High multi cylinder
ZE135
2-lead wire
—
10 to 28VDC
4 to 20 mA (at 25°C [77ºF], 10 mA at 60°C [140ºF])
—
4V MAX.
0.7 mA MAX. (24VDC, 25°C [77ºF])
PCCV0.2SQ
×
2-leads (brown, blue)
×
R
Note 3
ZE155
ZE175
4.5 to 28VDC
4.5 to 28VDC
50 mA MAX.
0.5V MAX. (at 20 mA for voltage below 10V)
50µA MAX. (24VDC)
PCCV0.15SQ
×
3-leads (brown, blue, black)
×
R
Note 3
ZE255
ZE275
4.5 to 28VDC
4.5 to 28VDC
50 mA MAX.
0.5V MAX. (at 20 mA for voltage below 10V)
50µA MAX. (24VDC)
PCCV0.15SQ
×
3-leads (brown, blue, black)
×
R
Note 3
Item
Wiring type
Lead wire direction
Power supply voltage
Load voltage
Load current
Consumption current
Internal voltage drop
Note 1
Leakage current
Response time
Insulation resistance
Dielectric strength
Shock resistance
Note 2
Vibration resistance
Note 2
Environmental protection
Operation indicator
Lead wire
Ambient temperature
Storage temperature range
Mass
Model
Note 1: Internal voltage drop varies depending on load current.
2: Measured by Koganei test standards.
3: Lead wire length
R
: A; 1000 mm [39 in.], B; 3000 mm [118 in.], G; 300 mm [11.8 in.] with M8 connector, ZE175
, ZE275
only
Horizontal
Vertical
Solid state type
Specifications
ZE101
0.1 V MAX. (at load current of DC 40 mA)
None
ZE102
3.0V MAX.
When ON, red LED indicator lights up
ZE201
0.1 V MAX. (at load current of DC 40 mA)
None
ZE202
3.0V MAX.
When ON, red LED indicator lights up
Item
Wiring type
Lead wire direction
Load voltage
Load current
Internal voltage drop
Note 1
Leakage current
Response time
Insulation resistance
Dielectric strength
Shock resistance
Note 2
Vibration resistance
Note 2
Environmental protection
Operation indicator
Lead wire
Ambient temperature
Storage temperature range
Contact protection
Mass
Model
Note 1: Internal voltage drop varies depending on load current.
2: Measured by Koganei test standards.
3: Lead wire length
ℓ
: A; 1000 mm [39 in.], B; 3000 mm [118 in.]
Horizontal
Vertical
Reed switch type
5 to 28VDC
40 mA MAX.
85 to 115VAC (r.m.s)
20 mA MAX.
10 to 28VDC
5 to 40 mA
85 to 115VAC (r.m.s)
5 to 20 mA
5 to 28VDC
40 mA MAX.
85 to 115VAC (r.m.s)
20 mA MAX.
10 to 28VDC
5 to 40 mA
85 to 115VAC (r.m.s)
5 to 20 mA
8 mA MAX. (24VDC)
3-lead wire NPN output
3-lead wire NPN output
8 mA MAX. (24VDC)
10 mA MAX. (24VDC)
3-lead wire PNP output
3-lead wire PNP output
10 mA MAX. (24VDC)
2-lead wire
0 mA
1 ms MAX.
100 M
Ω
MIN. (at 500VDC megger, between case and lead wire terminal)
1500VAC (50/60 Hz) 1 minute (between case and lead wire terminal)
294.2 m/s
2
[30 G] (non-repeated shock)
88.3 m/s
2
[9 G] (total amplitude 1.5 mm [0.059 in.], 10 to 55 Hz), resonance frequency 2570
±
250 Hz
IP67 (IEC standard), JIS C0920 (water-proof type)
PCCV0.2SQ
×
2-leads (brown, blue)
×
R
Note 3
0
〜
60
℃
[32
〜
140ºF]
−10
〜
70
℃
[14
〜
158ºF]
Required (Refer to contact protection countermeasure described in page
C
)
15 g [0.53 oz.] (lead wire length A: 1000 mm [39 in.]), 35 g [1.23 oz.] (lead wire length B: 3000 mm [118 in.])
1 ms MAX.
100 M
Ω
MIN. (at 500VDC megger, between case and lead wire terminal)
500VAC (50/60 Hz) 1 minute (between case and lead wire terminal)
294.2 m/s
2
[30 G] (non-repeated shock)
88.3 m/s
2
[9 G] (total amplitude 1.5 mm [0.059 in.], 10 to 55 Hz)
IP67 (IEC standard), JIS C0920 (water-proof type)
When ON, red LED indicator lights up
0
〜
60ºC [32
〜
140ºF]
−10
〜
70ºC [14
〜
158ºF]
15 g [0.53 oz.] (lead wire length A: 1000 mm [39 in.]), 35 g [1.23 oz.] (lead wire length B: 3000 mm [118 in.]), 15 g [0.53 oz.] (lead wire length 300 mm [11.8 in.] with M8 connector)
ZE235
2-lead wire
—
10 to 28VDC
4 to 20 mA (at 25°C [77°F], 10 mA at 60°C [140°F])
—
4V MAX.
0.7 mA MAX. (24VDC, 25°C [77ºF])
PCCV0.2SQ
×
2-leads (brown, blue)
×
R
Note 3
Summary of Contents for YMDA Series