background image

Specifications

List of controller specifications

Item

Specifications

Power 

supply

Voltage

12 to 24 VDC ±10% *Use a Class 2 

power supply.

Sensor head supply 

voltage

12 to 24 VDC ±10% (*Depending on 

power supply voltage)

Consumption 

current

100 mA MAX. (Not including supply 

power to sensors)

Sensor input

Number of 

connected sensors

4

Maximum 

consumption current 

for sensor head

Each channel; under 150 mA

Input voltage range

1.0 to 5.0 VDC

Input impedance

1 M

Ω

Maximum applied 

voltage

5.6 V MAX.

Compatible sensor 

heads

MSU-PH-EA: -101.3 to 0.0 kPa  

[-29.9 to 0.000 inHg]

MSU-PH-ER: -100.0 to 220.0 kPa  

[-29.5 to 65.0 inHg]

MSU-PH-EM: -100 to 1000 kPa  

[-29.5 to 295 inHg]

FS-R05: -500 to 500 mL/min  

[-0.018 to 0.018 ft

3

/min]

FS-R3: -3.00 to 3.00 L/min  

[-0.106 to 0.106 ft

3

/min]

FS-10: 0.00 to 10.00 L/min  

[0.000 to 0.353 ft

3

/min]

Any sensor (set display at 1 V and 5 V)

External  

output

Output points

4

Output method

MSU-

    NPN open collector

MSU-

-PNP

    PNP open collector

Responsiveness

5 ms (when filter function is OFF)

Load voltage

30 V MAX.

Load current

50 mA MAX.

Internal voltage 

drop

NPN: 0.3 V MAX. (when 5 mA)

PNP: 2V MAX. (when 50 mA)

Output mode

Hysteresis mode, window comparator 

mode 1, window comparator mode,  

high mode, low mode, output OFF mode

Repeatability

1% FS

Functions

Threshold value setting, response differential 

setting, output inversion, ON delay

External  

imput

Input points

4

Functions

Zero reset or import reference pressure

Display

Display type

LCD display

Color

2 color display (red, green)

Number of digits 

displayed

(-) 4-digit display

Display resolution

MSU-PH-EA: 0.1 kPa [0.030 inHg]

MSU-PH-ER: 0.1 kPa [0.030 inHg]

MSU-PH-EM: 1 kPa [0.295 inHg]

FS-R05: 1 mL/min [0.000 ft

3

/min]

FS-R3: 0.01 L/min [0.000 ft

3

/min]

FS-10: 0.01 L/min [0.000 ft

3

/min]  

(if more than 5.00 L/min [0.177 ft

3

/min],  

then it is 0.05 L/min [0.002 ft

3

/min])

Switch output 

confirmation LED

Lit when external output is ON 

 (red LED)

Display channel 

confirmation LED

LED that corresponds to the currently 

displayed pressure lights (green LED)

Display accuracy

1%F.S. ±1digit (Controller stand alone)

Functions

Auto scan, zero adjust, display update 

cycle, backlight setting, setting for turning 

LEDs off, peak-hold, bottom-hold

Filter

(Applicable to both SW output and display)

OFF to level 7

Item

Specifications

Main unit keys

Up key: 

  Down key: 

  Enter key:   

Communication

Communications 

standard

RS232C

RS485

Communication 

speed

9600, 19200 bps

9600, 19200, 

38400, 57600, 

115200 bps

Address settings

None

Rotary switches

Number of daisy 

chain connections

Not applicable

MAX. 16

General

Operating 

temperature range

-10 to 50

 [14 to 122°F];  

when stored: -20 to 80

 [-4 to 176°F] 

(non-condensation, non-freezing)

Operating humidity 

range

35 to 85% RH

Dielectric strength

500 VAC for 1 minute 

Insulation 

resistance

100 M

Ω

 MIN (at 500VDC megger)

Vibration resistance

Endurance: 10 to 55 Hz; secondary 

amplitude: 1.5 mm [0.059 in.], 2 hours 

in each direction (XYZ)

Shock resistance

Endurance: 490 m/s

2

 [50 G],  

5 times in each direction (XYZ)  

(when not electrified)

Materials

Surface seal: PET; case: PBT, PC; 

mounting screws: brass

Altitude

2000 m [6562 ft] or less

Mass

50 g [1.764 oz] (not including other 

optional cables)

Environment

Indoor use, POLLUTION DEGREE 2

Standard

CE, UL (Recognition)

Note: Only NPN type is UL compliant.

List of pressure sensor head specifications

Item

Negative 

pressure

Compound pressure

Model

MSU-PH-EA MSU-PH-ER MSU-PH-EM

Media

Air or non-corrosive gas

Power 

supply

Voltage

24 VDC ±10%

Consumption 

current

6 mA MAX.

Analog 

output

Output voltage

1 to 5 V

Zero-point 

voltage (Vzero)

1.00 ±0.05

3.75 ±0.05

4.64 ±0.05

Span voltage

4.00 ±0.07 (reference value)

Temperature 

characteristics Vzero: within ±30 mV; span: within ±2% F.S.
Output current 1 mA max. (load resistance of 5 k

Ω

 or more)

General

Operating 

pressure range 

kPa [inHg]

-101.3 to 

0 [-29.9 to 

0.000]

-100.0 to 

220.0 [-29.5 

to 65.0]

-100 to 1000 

[-29.5 to 295]

Proof pressure 

kPa [inHg]

900 [265.9]

1500 [443]

Operating 

temperature 

range

0 to 50

 [32 to 122°F];  

when stored: -20 to 80

 [-4 to 176°F]  

(when stored: humidity of less than 65% 

RH, atmospheric pressure)

Operating 

humidity range

35 to 85% RH

Insulation 

resistance

100 M

Ω

 MIN (at 500VDC megger)

Dielectric 

strength

500 VAC   1 minute

Altitude

2000 m [6562 ft] or less

Environment

Indoor use, POLLUTION DEGREE 2

Mass

40 g [1.411 oz]

Standard

CE, UL (Recognition)

Note: UL compliant when connected to NPN controller.

6

Summary of Contents for MSU Series

Page 1: ...rollers can be centrally managed Maximum of 64 sensor heads Do you have these problems Including other manufacturer s products RS232C communication RS485 communication Connect any sensor with 1 to 5 V output Pressure and flow sensor heads are available 5 output mode patterns There are too many types of sensors pressure flow etc inside the equipment Monitoring and controlling each sensor is too com...

Page 2: ...sensor can be connected Multi channel multi sensor controller MSU Series L1 L2 Hysteresis H2 Hysteresis H1 L1 Hysteresis H1 L1 Hysteresis H1 L2 OFF lit L1 ON lit When L1 L2 When L1 L2 No output when L1 L2 L1 ON lit L2 OFF lit Switch output L1 L2 Hysteresis ON t Hysteresis Mode Window comparator mode 1 Window comparator mode High Mode Low Mode Mode for turning output ON within the set value range f...

Page 3: ... unit Network unit Daisy chain Max 16 units 64 heads Upper controller Upper controller Upper controller Example connection 1 MSU Example connection 2 MSU 232 Example connection 3 MSU 485 Equipped with communication mode compatible with existing models Pressure sensor head or Flow rate sensor head or Any 1 to 5 V sensor Pressure sensor head or Flow rate sensor head or Any 1 to 5 V sensor Note1 Note...

Page 4: ...ury WARNING Because Koganei products may be used under a wide variety of conditions decisions concerning conformance with a particular system should be made upon the careful evaluation by the person in charge of system design Assurances concerning expected system performance and safety are the responsibility of the designer who decides system conformity Be sure to use the latest catalogs and techn...

Page 5: ...e the sensor head instantly Furthermore even with multi channel multi sensor controllers turning on SW output while the load is short circuited may damage the products due to over current Example of short circuit load Output lead wire for sensor output SW output is directly connected to the power supply ATTENTION When considering the possibility of using this product in situations or environments ...

Page 6: ...m the front of the panel hole 2 Insert the sensor controller from the back of the mounting body 3 From the back of the position in 2 place the mounting holder on the mounting body groove and insert it 4 Set the separately sold protective front cover in place For removal follow the above procedure in reverse using a screwdriver or other tool to remove the mounting holder To mount the sensor head an...

Page 7: ...can zero adjust display update cycle backlight setting setting for turning LEDs off peak hold bottom hold Filter Applicable to both SW output and display OFF to level 7 Item Specifications Main unit keys Up key Down key Enter key Communication Communications standard RS232C RS485 Communication speed 9600 19200 bps 9600 19200 38400 57600 115200 bps Address settings None Rotary switches Number of da...

Page 8: ...W1 white Pin 4 SW2 green Pin 5 SW3 yellow Pin 6 SW4 brown Manufactured by Sumitomo 3M Limited 37104 3101 Data input Pin 1 V brown Pin 2 sensor output black Pin 3 0 V blue Pin 4 IN Manufactured by JST Data input output RS485 Pin 1 A white Pin 2 B pink Pin 3 0 V yellow Pin 4 N C Pin 5 N C Connector type Item Specifications Made by JST B11B XASK 1 Power supply 1 pin 24V red 2 pin 0V black Data input ...

Page 9: ...V 1 2 3 RS 232C communication cable Black 0V white RXD Red TXD Host device with RS 232C built in R1 innter circuit RS 232C type 1 2 3 RS 485 communication cable White A Pink B Yellow 0V Host device with RS 485 built in RS 485 type 1 2 3 IN2 1 2 3 4 R 2 IN3 1 2 3 4 R 3 IN4 1 2 3 4 R 4 F Load Load Load Sensor head Channel 2ch Sensor head Channel 3ch Sensor head Channel 4ch Brown V Blue 0V Brown V Bl...

Page 10: ...5 communication 4 Pressure sensor head Piping options Blank None UR4 φ4 reducer UR6 φ6 reducer M5 M5 inline Cable orientation L Vertical out S Horizontal out Pressure range EA 101 3 to 0 kPa 29 9 to 0 inHg ER 100 to 220 kPa 29 5 to 65 0 inHg EM 100 to 1000 kPa 29 5 to 295 inHg MSU PH Power supply switching communication cable MSU K IBFL K IBM2A H1 1 Protective front cover C can be selected only if...

Page 11: ...ch 4ch SENSOR 1 V IN 0V ANLG 4 3 2 Enlarged diagram of wiring labels The label above shows the MSU 232 For the MSU no communications 7 to 9 are N C Only NPN type is UL compliant Note 1 The diagram shows when the address is 0 5 0 197 30 1 181 32 1 260 8 3 0 327 27 6 1 087 2 65 0 104 Address setting 0 to F Note 1 Sensor connector RS 485 communication connector Power switch output connector Power swi...

Page 12: ...0 118 For mounting 2 M5 depth 4 0 157 Cap KOGANEI Cap color EA Grey ER Pink EM Blue 3000 118 Pin 1 5 0 197 14 9 0 587 15 6 0 614 12 4 0 488 5 9 0 232 4 3 2 1 50 1 969 φ2 6 0 102 3 7 0 146 5 0 197 12 0 472 11 0 433 9 8 0 386 10 0 394 20 0 787 7 0 276 17 0 669 O ring Detection port φ3 0 118 Cap color EA Gray ER Pink EM Blue 1 5 0 059 2 φ2 1 0 083 6 4 0 252 Mini clamp wire mounting plug Mounting hole...

Page 13: ...unting panel thickness of 1 to 3 2 mm 0 039 to 0 126 in mm 2 For adjacent mounting provide at least the amount of spacing between holes as shown to the right 3 DIN43700 standard Model L MSU K 3HE 3000 118 MSU K 5HE 5000 197 29 8 1 173 9 5 0 374 50 1 969 L φ5 1 0 201 6 wires Power switch output cable φ4 2 0 165 Serial communication cableNote 3 wires 7 0 276 MSU K L MSU K LD Model L MSU K 3L 3000 11...

Page 14: ...ange 0 03 FS kPa 70 to 0 kPa 20 678 to 0 inHg Temperature characteristics 0 0ℓ min 0 000 ft3 min 0 1 FS C 0 0ℓ min 0 000 ft3 min 0 1 FS C 0 0ℓ min 0 000 ft3 min 0 1 FS C 1 5ℓ min 0 053 ft3 min 0 15 FS C 0 3ℓ min 0 011 ft3 min 0 15 FS C 5 0ℓ min 0 177 ft3 min 0 2 FS C Voltage 24 VDC Supply from sensor controller Allowable voltage fluctuation range In the 21 6 to 26 4 VDC range 2 FS or lower relativ...

Page 15: ...5 0 6 0 7 0 8 0 9 0 10 0 Output V Flow rate ℓ min ANR FS R05 FS R3 FS 10 1ℓ min ANR 0 035 ft3 min SCFM 10 5 0 413 32 5 1 280 17 0 669 5 3 0 209 5 25 0 207 5 25 0 207 5 3 0 209 5 7 0 224 11 2 0 441 10 2 0 402 2 M5 0 8 Inflow port 2 φ3 1 0 122 mounting hole Cover Connector connection port Sensor head connector 12 4 0 488 15 6 0 614 14 9 0 587 5 9 0 232 5 0 197 Pin 1 2000 20 79 0 787 4 3 2 1 FS Dimen...

Page 16: ... only such items supplied by KOGANEI CORP The products of other manufacturers are covered only by such warranties made by those original manufacturers even though such items may have been included as the components The specifications are subject to change without notice Warranty Period Koganei Responsibility Limitations 9 19 AB KOGANEI CORP PRINTED IN JAPAN URL http www koganei co jp E mail overse...