●❶
CAUTION
Read the safety precautions on page
3
before using this product.
Pressure sensor head variations
Output mode setting
Flow rate sensor head variations (existing models)
*Not UL/CE compliant.
* To use Window Comparator Mode 1 and Window Comparator Mode, setting must be L1 > L2.
Pressure sensor head
options
Any sensor that can be connected
-101.3 kPa
0 kPa
-3
ℓ
/min
-500
m
ℓ
/min
500 m
ℓ
/min
10
ℓ
/min
3
ℓ
/min
-100 kPa
-100 kPa
0
ℓ
/min
220 kPa
1000 kPa
For negative
pressure
MSU-PH-EA-
□
FS-R3
Compound
pressure
(for
low pressure)
MSU-PH-ER-
□
FS-R05
Compound
pressure
(for
high pressure)
MSU-PH-EM-
□
FS-10
MSU-PH-EA-S
MSU-PH-ER-S
MSU-PH-EM-S
Sensor head
Sensor head
Reducer connection type
φ
4 [0.157]: −UR4
φ
6 [0.236]: −UR6
Female threaded
connection type
M5: −M5
Operating pressure range
1 kPa = 0.295 inHg
Operating flow range
1
ℓ
/min = 0.035 ft
3
/min
-100
-3
0
0
100
3
200
1000 (kPa)
10 (
ℓ
/min)
Extensive output settings can support your application!
Any type of sensor can be connected!
Multi-channel multi-sensor controller
MSU Series
L1
L2
Hysteresis H2
Hysteresis H1
L1
Hysteresis H1
L1
Hysteresis H1
L2(OFF lit)
L1(ON lit)
When L1 < L2
When L1 > L2
No output when L1 = L2.
L1(ON lit)
L2(OFF lit)
Switch output
L1
L2
Hysteresis
ON
t
• Hysteresis Mode
• Window comparator mode 1
• Window comparator mode
• High Mode
• Low Mode
Mode for turning output ON within the set value range for L1 and L2
(OFF point depends on response differential setting)
Mode for turning output ON when above the ON point
(OFF point depends on response differential setting)
Mode for turning output ON when below the ON point
(OFF point depends on response differential setting)
Mode for setting the ON point and OFF point
(mode that does not turn on when between L1 and L2 while rising)
Mode for turning output ON within the set value range for L1 and L2
(OFF point depends on response differential setting)
Does not turn on when entering range while rising
You can use a 1 to 5 V linear
output sensor by setting the
display value at 5 V and display
value at 1 V.
1V
5V
Display value for 1 V
Display value at 5 V
1 to 5 V output type