background image

 
 
 
 
Read all of the instructions before use, and retain this user guide for future reference. 

SAFETY INSTRUCTIONS 

WARNING! 

When installing and using this electrical equipment, basic safety precaution should always 

be followed, including the following: 

Important safety instructions – read and follow all instructions.

 

 

WARNING: 

 

WARNING:

 This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning use 

of the appliance by a person responsible for their safety. Children should be 

supervised to ensure that they do not play with the appliance. 

 

Risk of Accidental Drowning:

 Extreme caution must be exercised to prevent 

unauthorized access by children. To avoid accidents, ensure that children cannot 

use this spa unless they are supervised at all times. 

 

For safety around children and to minimise drowning risk, always fit the spa cover 

after each use. 

 

RISK OF INJURY:

 Do not operate spa if inlet or outlet pipes are broken or missing. 

Never attempt to replace the inlet and outlet pipes. Contact help.kogan.com for 

assistance. 

 

Risk of electric shock:

 Install at least 2 metres from all metal surfaces. 

 

Risk of electric shock:

 Never operate any electrical appliance when in your spa or 

when your body is wet. Do not place any electrical appliance (such as a light, 

telephone, radio or television) within 2 metres of spa. 

 

TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS RAINING. 

 

WARNING:

 Always keep plug dry. NEVER plug or unplug with a wet hand. 

 

WARNING:

 For electrical safety, a leakage current detecting device is incorporated 

in the power cord. If leakage current exceeding 10mA is detected, the device will cut 

off the power supply. In the event of cut-off, unplug the spa and stop using at once. 

Contact help.kogan.com for assistance in resetting the space. Do not attempt to 

reset the spa by yourself.  

 

Caution:

 In order to avoid a hazard due to inadvertent resetting of the thermal cut-

out, this appliance must not be supplied through an external switching device, 

such as a timer or connected to a circuit that is regularly switched on and off by the 

utility. 

              SAFETY & WARNINGS 

Summary of Contents for IBIZA KASPABWIBZA

Page 1: ...IBIZA INFLATABLE PORTABLE OUTDOOR HOTTUB MASSAGE SPA 4 6 PERSONS KASPABWIBZA...

Page 2: ......

Page 3: ...INJURY Do not operate spa if inlet or outlet pipes are broken or missing Never attempt to replace the inlet and outlet pipes Contact help kogan com for assistance Risk of electric shock Install at lea...

Page 4: ...ated or fixed so that they cannot fall into the spa pool The plug of the pump shall be more than 3 5 metres away from the spa at all times It is necessary to have the plug accessible after installatio...

Page 5: ...cation can greatly increase the risk of fatal hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level that is several degrees above the normal body temperature of 37...

Page 6: ...xit the spa slowly and cautiously Wet surfaces are slippery To avoid damage to the pump the spa must never be operated unless the spa is filled with water Immediately leave spa if the user feels uncom...

Page 7: ...Filter cartridge x2 13 P61726ASS18 x1 14 P61727ASS18 x1 15 P05346 x1 16 P6609ASS16 x1 17 P05347 x1 COMPONENTS Note Examine equipment before use Notify Kogan com support of any damaged or missing parts...

Page 8: ...requirements if you install the spa indoors Humidity is a natural side effect with spa installation Determine the effects of airborne moisture on surfaces exposed wood paper etc in the proposed locati...

Page 9: ...r Position the spa liner outdoor in the desired position connect the spa heater and fill with water Important The water temperature used to fill the spa must be above 6 C otherwise when you begin to o...

Page 10: ...Step 1 Step 2 Step 3 Step 4 Inflation time for reference only may not be exact INSTALLATION P6609ASS16...

Page 11: ...Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11...

Page 12: ...ipment and surrounding items The spa is a class I electrical appliance and must be connected directly to a grounded socket It is recommended to only use a socket which is resistant to humidity and cap...

Page 13: ...inflating you will notice that air will be expelled from the area where the air hose connects to the pump this is normal for technique requirements Important Don t cover the holes on the base of the...

Page 14: ...pa A Lock Unlock Button F On Off Button B Power Saving Timer Button G Temperature Decrease C Heat Button H Celsius Fahrenheit Toggle D Massage System Button I Water Filter Button E Temperature Increas...

Page 15: ...10 seconds to confirm the setting The 0 LED will light steadily and the countdown to heater activation will begin To modify the timer settings Press the button and use the or button to adjust Cancel...

Page 16: ...button for 2 seconds to active the control panel buttons and the light turns to green Press this button for 2 seconds to turn off all currently activated functions H CELSIUS FAHRENHEITTOGGLE The tempe...

Page 17: ...er a long period of inactivity be sure to press the reset button on the pump using a small and thin object If the temperature on the control panel or the water temperature has not changed 4 5 hours af...

Page 18: ...cover the spa with the spa cover whenever the heating function is activated Leaving the spa uncovered will increase the heating duration required When the spa is assembled with water do not switch off...

Page 19: ...please block the hoses to prevent water from escaping then disconnect the pump screw on the cap P00217 to avoid water coming out from the air pipe Cover Maintenance The cover shall be cleaned inside...

Page 20: ...mistry and chlorine or bromine tablets do not use granules with the chemical dispenser Water quality will be directly related to frequency of use number of users and overall maintenance of the spa The...

Page 21: ...Alkalinity Free Chlorine 7 4 7 6 80 120ppm 2 4ppm Note Damage resulting from chemical imbalance is not covered by the warranty Pool chemicals are potentially toxic and should be handled with care Ther...

Page 22: ...o extend the life of the spa We recommend using the pump to blow dry the spa pump and pipes Remove the filter sets and discard the used filter cartridges Re attach the two stopper caps onto the spa s...

Page 23: ...el patch 3 Press patch over area to be repaired 4 Wait 30 seconds before inflation ForTritech PVC material If the spa is torn or punctured use the provided PVC repair patch and glue not included follo...

Page 24: ...pump and wait two hours until the pump has cooled Insert the plug and press the Massage System Button Press the Massage System Button to reactivate Pump adapters are not level with the spa adapters O...

Page 25: ...nance Pay close attention to the chemical manufacturer s instructions Water leaks from the adapters between the pump and spa Seals are missing inside the pump adapters Seals are not in the correct pos...

Page 26: ...rs The washers within the spa couplings may have become perished or worn Remove the 2 stopper caps before heating refer to Installation section of this user guide Remove the filter set from inside the...

Page 27: ...pump push the pump s reset button The pump s thermometer connections have issues The pump s thermometer connectors are not working The pump s thermometer is broken Contact kogan com for support The ma...

Page 28: ...Capacity 4 6 adults Dimensions 1 80 m x 1 80 m x 66 cm Inflation pressure 0 8 PSI 0 055 Bar Litres 778 L SPECIFICATIONS...

Page 29: ...NOTES...

Page 30: ......

Page 31: ......

Page 32: ...ion We hope that this user guide has given you the assistance needed for a simple set up For the most up to date guide for your product as well as any additional assistance you may require head online...

Reviews: