Error Codes
Causes
Reasons
Solution
The water flow
sensors work
without pressing
the filter or heat
button.
•
The water flow sensor flags
didn’t fall back into the
correct position.
•
The water flow sensors are
broken.
Unplug, and gently strike the side of
the pump, then plug it back in.
After starting or
during the
functions of
filtering or/and
heating, the water
flow sensors do
not detect water
flow.
•
You forgot to remove the 2
stopper caps from inside
the pool.
•
Filter cartridges are dirty.
•
Activate the filter or heat
system and put your hand
in front of the outlet pipe
inside the pool to check if
you can feel water flowing
out.
a)
If no water flows out the
water pump is broken.
b)
Water flows out but the
alarm “E02” appears,
the water flow sensors
are broken.
•
Filter blockage
•
Bent pipes or poor water
flow through the plastic
pipes of the liner
•
Debris screens are blocked:
Debris screens can
become blocked by hard
water due to calcium build-
up.
•
Perished washers
•
The washers within the spa
couplings may have
become perished or worn.
•
Remove the 2 stopper caps before
heating, refer to Installation section
of this user guide.
•
Remove the filter set from inside
the pool and push the filter or heat
button. If no alarm appears, clean
or change the filter cartridges
install the filter set inside the pool.
•
Clean the filter and check for
damage. Replace or re-install as
necessary.
•
Please check through the spa
connection to see if the pipes are
bending.
•
Empty the spa and place a garden
hose inside the pipes to wash the
debris. To be sure all debris are
removed, perform the operation
from the outside and inside of the
spa.
•
Use a toothbrush to remove any
stubborn debris.
•
Check the washers inside the
coupling for damage. Unscrew the
couplings and remove the washer
for further inspection.
The pump’s
thermometer
reads the water
temperature
below 4°C.
•
The water temperature is
lower than 4°C
•
If the water temperature is
higher than 7°C, the
pump’s thermometer is
broken.
The spa is not designed to operate
with water temperatures lower than
4°C. Unplug the pump and only re-
start the pump when the water
temperature reaches 6°C.