Koehler K259 Series Operation And Instruction Manual Download Page 8

K259XX Constant Temperature Water Bath  

Operation and Instruction Manual 

 

K295XX-Manual 

-

4- 

Our  instrument  manual  will  include  this  compliance  statement  and  indicate  that  any  collection  of  materials  will  be 
handled by their authorized distributor. In the event that the distributor is unreachable or is no longer a distributor for 
Koehler Instrument, Co., other arrangements may be made including accepting the materials directly. 
 
Recycling  is  free  of  charge.  Shipping  is  the  responsibility  of  the  end  users.  Whether  shipping  to  a  distributor  or  to 
Koehler directly, safe, properly declared, and labeled packaging and shipping expenses are the sole responsibility of 
the end user. 
 

WEEE Marking 

 
 
 
 
 
 
 
 
 
 
Since  Koehler  products  are  subject  to  the  WEEE  Directive  we  must  display  the  WEEE  symbol  shown  above  in 
accordance  with  European  Standard  EN  50419  on  the  equipment.  It  must  be  indelible,  at  least  5mm  in  height,  and 
clearly legible. If the equipment is too small the mark must be in the product literature, guarantee certificate, or on the 
packaging. Rules on marking are established in section 49 of the WEEE Order. 
 
Koehler Instrument Company, Inc. 
c/o RECYCLING 
1595 Sycamore, Ave. 
Bohemia, NY 11716 
 
As a minimum the following substances, preparations and components have to be removed from any separately 
collected WEEE: 
- Mercury containing components, such as switches or backlighting lamps (compact fluorescent lamps, CFL), 
- Batteries 
- Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters (about 4 sq in.), 
- Toner cartridges, liquid and pasty, as well as color toner, 
- Chlorofluorocarbons (CFC), hydrochlorofluorocarbons (HCFC) or hydrofluorocarbons (HFC), hydrocarbons (HC) 
- Liquid crystal displays (together with their casing where appropriate) of a surface greater than 100 square 
centimeters and all those back-lighted with gas discharge lamps, 
- External electric cables 
- Components containing refractory ceramic fibers as described in Commission Directive 97/69/EC of 5 December 
1997 adapting to technical progress Council Directive 67/548/EEC relating to the classification, packaging and 
labeling of dangerous substances (2), 
- Electrolyte capacitors containing substances of concern (height > 25 mm, diameter > 25 mm or proportionately 
similar volume) 
 
2. The following components of WEEE that is separately collected have to be treated as indicated: 
- Equipment containing gases that are ozone depleting or have a global warming potential (GWP) above 15, such as 
those contained in foams and refrigeration circuits: the gases must be properly extracted and properly treated. Ozone-
depleting gases must be treated in accordance with Regulation (EC) No 2037/2000 of the European Parliament and of 
the Council of 29 June 2000 on substances that deplete the ozone layer (4).

 

 

 
 
 
 
 
 

Summary of Contents for K259 Series

Page 1: ... Avenue Bohemia New York 11716 1796 USA Toll Free 1 800 878 9070 US only Tel 1 631 589 3800 Fax 1 631 589 3815 http www koehlerinstrument com e mail info koehlerinstrument com Petroleum Testing Analysis Instrumentation Custom Design Manufacturing K259XX Constant Temperature Water Bath ...

Page 2: ......

Page 3: ...red in conformance with the applicable standards set forth in this certification Specifications ASTM D1657 GPA 2140 This unit is tested before it leaves the factory to ensure total functionality and compliance to the above specifications and ASTM standards Test and inspection records are on file for verification Jesse Kelly Application Engineer Koehler Instrument Company ...

Page 4: ......

Page 5: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 1 ...

Page 6: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 2 ...

Page 7: ...nformation on subsequent processing or recycling prior to disposal of the equipment http www dpa system dk en WEEE Products Private or professional use Responsibility for Registration and Annual Reporting Koehler will not sell directly to end users in the EU and so has no responsibility to register within each EU state and to make annual reports Koehler declares that this responsibility is born by...

Page 8: ...ely collected WEEE Mercury containing components such as switches or backlighting lamps compact fluorescent lamps CFL Batteries Printed circuit boards if the surface of the printed circuit board is greater than 10 square centimeters about 4 sq in Toner cartridges liquid and pasty as well as color toner Chlorofluorocarbons CFC hydrochlorofluorocarbons HCFC or hydrofluorocarbons HFC hydrocarbons HC ...

Page 9: ...rmation and Warnings 7 3 Getting Started 7 3 1 Packing List 7 3 2 Unpacking 7 3 3 Setup 8 4 Descriptions 9 4 1 Instrument Descriptions 9 4 2 Temperature Controller Operation 11 5 Operation 12 6 Maintenance 12 6 1 Routine Maintenance 12 6 2 Replacement Parts 12 7 Wiring Diagrams 13 7 1 K25900 115V 13 7 2 K25995 230V 50Hz 14 7 3 K25990 230V 60Hz 15 8 Service 16 9 Storage 16 10 Warranty 16 11 Returne...

Page 10: ...for a full range of accurate and reliable instrumentation as well as support for your laboratory testing programs Please do not hesitate to contact us at any time with your inquiries about equipment tests or technical support 1 2 Recommended Resources and Publications 1 American Society for Testing and Materials ASTM 100 Barr Harbor Drive West Conshohocken Pennsylvania 19428 2959 USA Tel 1 610 832...

Page 11: ...hemical Reagents Information The use of chemicals and reagents with this equipment may exhibit potential hazards Any use must be familiarized with the possible dangers before use We recommend consulting the Material Data and Safety Sheet MSDS on each chemical reagent for safety information MSDS information can be easily located on the Internet at http siri uvm edu or http www sigma aldrich com 3 G...

Page 12: ...trument on a firm level surface in an area with adequate environmental control Environmental Conditions The instrument environment must comply with the following conditions for proper setup No Low Dust No direct sunlight Not near heating or AC ventilation ducts No Vibrations Clearance from other instruments Temperature Range 5 to 40 C Elevation to 2000 meters Relative Humidity 80 Filling the Bath ...

Page 13: ...mometer to verify bath temperature displayed on temperature controller 5 Stirrer Motor To agitate bath medium in order to provide temperature uniformity in the apparatus 6 Temperature Measurement Probe Measures direct temperature of bath and communicates with temperature controller for display Figure 2 Instrument Descriptions_Front Panel 7 Line Switch For powered on entire unit Temperature control...

Page 14: ... emptying bath medium to appropriate receptacle 16 Bath Outlet Connect insulated tubing from mechanically refrigerated chiller inlet Figure 6 Item 19 Figure 4 Instrument Descriptions_ Back_115V_230V 60Hz 17 Chiller Power Receptacle_115V For connecting mechanically refrigerated chiller Figure 1 Item 3 power cord to constant temperature bath Figure 1 Item 1 NOTE Plug type for 115V 60Hz and 230V 60Hz...

Page 15: ... to fully equilibrate before proceeding with any testing Temperature Calibration This routine allows the digital temperature controller to be calibrated to a certified thermometer a Use a certified calibrated measuring device to acquire the temperature Calculate the difference between the measuring device and the Process value displayed on the controller b Press the program key two times until PCt...

Page 16: ... Allow time for the bath temperature to equilibrate 7 Proceed with performing the test according to the test methods prescribed in Section 1 2 of this document 6 Maintenance WARNING Disconnect power to the unit before servicing to avoid exposure to high voltages and or temperatures which may result in personal injury or death If you have any questions about maintaining your equipment please do not...

Page 17: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 13 7 Wiring Diagrams 7 1 K25900 115V ...

Page 18: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 14 7 2 K25995 230V 50Hz ...

Page 19: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 15 7 3 K25990 230V 60Hz ...

Page 20: ...he return of the product to the factory The sole responsibility of Koehler Instrument Company and the purchaser s exclusive remedy for any claim arising out of the purchase of any product is the repair or replacement of the product In no event shall the cost of the purchaser s remedy exceed the purchase price nor shall Koehler Instrument Company be liable for any special indirect incidental conseq...

Page 21: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 17 Notes ...

Page 22: ...K259XX Constant Temperature Water Bath Operation and Instruction Manual K295XX Manual 18 Notes ...

Reviews: