Chapter 9 Simple fault diagnosis
MDC-5000 Series
0093153004-00
9-6
9.5
Need to confirm serial input
This procedure is applied to confirm serial input of Processor unit.
Serial input of connectors can be confirmed with the following 4 connectors:
AIS (J2), NMEA (J3, J5 or J6).
1
Press MENU
key to display “Menu”.
Select [MAINTENANCE] => [I/O] => [SERIAL MONITOR] => select [J3], [J5], [J6], [AIS] or [ALL],
and press ENT key.
[ALL] can confirm the data of all ports at a time.
2
Input data will be displayed.
Since the data keeps coming in and the display keeps changing it may be hard to observe the
sentences.
By pressing ENT key, data display will stop temporarily to confirm data content.
3
Move joystick to left to complete.
Data confirming item in step 2
In the case that data is not displayed: Confirm input data device connected to Processor unit.
In the case that data is displayed but is garbled: Confirm baud rate.
Summary of Contents for MDC-5004
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 28: ... This page intentionally left blank ...
Page 38: ... This page intentionally left blank ...
Page 110: ... This page intentionally left blank ...
Page 114: ... This page intentionally left blank ...
Page 142: ... This page intentionally left blank ...
Page 150: ... This page intentionally left blank ...
Page 156: ...Chapter 10 Specifications MDC 5000 Series 0093153004 00 10 6 Unit mm inch RB809 ...
Page 188: ... This page intentionally left blank ...
Page 192: ......