Chapter 12 Communication with external navigation system
KGP-925
12-4
0093192502-00
Following is an example of Working route data. Refer to IEC61162-1 for detail.
$ECRTE,1,1,w,northsea,WP_001,APORTS,BIRAND,WP_004,myName,WP_006*76
$ECWPL,5355.91,N,00840.22,E,WP_001*20
$ECWPL,5357.98,N,00833.37,E,APORTS*28
$ECWPL,5402.22,N,00805.29,E,BIRAND*25
$ECWPL,5411.81,N,00721.94,E,WP_004*26
$ECWPL,5414.39,N,00616.22,E,myName*77
$ECWPL,5417.69,N,00450.70,E,WP_006*2B
Working route has priority and route navigation by Working route automatically begins by reception of
working route data. It is updated every time Working route data is received.
12.2.4 Error message
Following indications are displayed during transfer of data from an external navigation system for user’s
reference.
Press (CLR) key to erase the indication and try transfer again.
*
Max. number of character is same as Complete route
w: Working route
Max. character number in a line is 124 bytes including
Max. 10 waypoints
(
Over10 is ignored
)
The last passed waypoint
Current waypoint
ERROR
overflow
ERROR
checksum
ERROR
format
Number of characters in a line is exceeding 124 bytes.
Checksum error.
Sentence format error.
Indicating route navigation by Working route
data from external system.