SERVICE MANUAL
70
10SEP02 – 9B8949
[10]
To begin at mode 1 again:
(a)
De-energize the PROCESSOR.
(b)
Energize the PROCESSOR.
(c)
Do
again.
[11]
When you complete the diagnostics:
(a)
De-energize the PROCESSOR.
(b)
Move DIP SWITCH SW02-4 to the “OFF” position.
(c)
Install the CONTROL BOX COVER. See
Removing the CONTROL BOX COVER
.
Checking the TEMPERATURE SENSOR
[1]
[2]
Does the ALARM emit 2 or 3 rapid beeps then 3
long beeps?
Important
The resistance of the TEMPERATURE SENSORS should be approximately 5.4 k ohm at 22
°
C (75
°
F).
[3]
If the ALARM emits a continual sound, observe the CONTROL BOARD:
H164_0034AC
FIX.
DEV.
RUN
Rep.
Dev. Temperature
Low
Ready
High
Service
Yes
No
a. The TEMPERATURE
SENSORS are
operating correctly.
b. Continue with
Continue with
“High s” blinks:
“Low t” blinks:
a. Check the DRYER TEMPERATURE SENSOR
SE52 for:
• open circuit
• short circuit
b. If necessary, install a new DRYER
TEMPERATURE SENSOR SE52.
a. Check the DEVELOPER TEMPERATURE
SENSOR SE51 for:
• open circuit
• short circuit
b. If necessary, install a new DEVELOPER
TEMPERATURE SENSOR SE51.