Adjustments
9B8949 – 10SEP02
49
Adjusting the Developer Temperature
[1]
Do
Removing the CONTROL BOX COVER
Developer Temperature, 32 - 35
°
C (89.6 - 95.0
°
F)
[2]
Set the developer temperature between
32.0 - 35.0
°
C (89.6 - 95.0
°
F).
(a)
Move SW05-1 to the “OFF” position.
(b)
Use the table to adjust SW03.
Developer Temperature, 35 - 38
°
C (95.0 - 100.4
°
F)
[3]
Set the developer temperature between
35.0 - 38.0
°
C (95.0 - 100.4
°
F).
(a)
Move SW05-1 to the “ON” position.
(b)
Use the table to adjust SW03.
[4]
Measure the temperature of the developer
solution.
Note
The temperature of the developer solution might not
match the set point. If necessary, you can adjust the
temperature.
[5]
Does the temperature of the developer solution
match the set point?
7 8
B
D
C
1
0
2
F
E
5
4
3
6
A
9
F
0
12
3
4
5
6
7 8 9 A
B
C
D
E
ON
4
3
2
1
DEV TEMP
ADD
SET
SW05
SW04
SW03
H164_0038AC
SW05-1 OFF, Adjust SW03:
Set
Point
Temperature
Set
Point
Temperature
0
32.0
°
C (89.6
°
F)
8
33.6
°
C (92.5
°
F)
1
32.2
°
C (90.0
°
F)
9
33.8
°
C (92.8
°
F)
2
32.4
°
C (90.3
°
F)
A
34.0
°
C (93.2
°
F)
3
32.6
°
C (90.7
°
F)
B
34.2
°
C (93.6
°
F)
4
32.8
°
C (91.0
°
F)
C
34.4
°
C (93.9
°
F)
5
33.0
°
C (91.4
°
F)
D
34.6
°
C (94.3
°
F)
6
33.2
°
C (91.8
°
F)
E
34.8
°
C (94.6
°
F)
7
33.4
°
C (92.1
°
F)
F
35.0
°
C (95.0
°
F)
SW05-1 ON, Adjust SW03:
Set
Point
Temperature
Set
Point
Temperature
0
35.0
°
C (95.0
°
F)
8
36.6
°
C (97.9
°
F)
1
35.2
°
C (95.4
°
F)
9
36.8
°
C (98.2
°
F)
2
35.4
°
C (95.7
°
F)
A
37.0
°
C (98.6
°
F)
3
35.6
°
C (96.1
°
F)
B
37.2
°
C (99.0
°
F)
4
35.8
°
C (96.4
°
F)
C
37.4
°
C (99.3
°
F)
5
36.0
°
C (96.8
°
F)
D
37.6
°
C (99.7
°
F)
6
36.2
°
C (97.2
°
F)
E
37.8
°
C (100.0
°
F)
7
36.4
°
C (97.5
°
F)
F
38.0
°
C (100.4
°
F)
Yes
No
a. Wait 45 minutes.
b. Check the developer
temperature again.
c. If the temperature is
correct, advance to
Continue with